A Review of Methods for Correction of Intensity Inhomogeneity in MRIUro Vovk, Franjo Pernuš, B. Likar|IEEE Transactions on Medical Imaging|2007 Medical image acquisition devices provide a vast amount of anatomical and functional information, which facilitate and improve diagnosis and patient treatment, especially when supported by modern quantitative image analysis methods. However, modality specific image artifacts, such as the phenomena of intensity inhomogeneity in magnetic resonance images (MRI), are still prominent and can adversely affect quantitative image analysis. In this paper, numerous methods that have been developed to reduce or eliminate intensity inhomogeneities in MRI are reviewed. First, the methods are classified according to the inhomogeneity correction strategy. Next, different qualitative and quantitative evaluation approaches are reviewed. Third, 60 relevant publications are categorized according to several features and analyzed so as to reveal major trends, popularity, evaluation strategies and applications. Finally, key evaluation issues and future development of the inhomogeneity correction field, supported by the results of the analysis, are discussed.
MRI intensity inhomogeneity correction by combining intensity and spatial informationUro Vovk, Franjo Pernu, Bo tjan Likar|Physics in Medicine and Biology|2004 We propose a novel fully automated method for retrospective correction of intensity inhomogeneity, which is an undesired phenomenon in many automatic image analysis tasks, especially if quantitative analysis is the final goal. Besides most commonly used intensity features, additional spatial image features are incorporated to improve inhomogeneity correction and to make it more dynamic, so that local intensity variations can be corrected more efficiently. The proposed method is a four-step iterative procedure in which a non-parametric inhomogeneity correction is conducted. First, the probability distribution of image intensities and corresponding second derivatives is obtained. Second, intensity correction forces, condensing the probability distribution along the intensity feature, are computed for each voxel. Third, the inhomogeneity correction field is estimated by regularization of all voxel forces, and fourth, the corresponding partial inhomogeneity correction is performed. The degree of inhomogeneity correction dynamics is determined by the size of regularization kernel. The method was qualitatively and quantitatively evaluated on simulated and real MR brain images. The obtained results show that the proposed method does not corrupt inhomogeneity-free images and successfully corrects intensity inhomogeneity artefacts even if these are more dynamic.