An official systematic review of the European Respiratory Society/American Thoracic Society: measurement properties of field walking tests in chronic respiratory disease

Sally Singh(Local Initiatives Support Corporation), Milo A. Puhan(Local Initiatives Support Corporation), Vasileios Andrianopoulos(Local Initiatives Support Corporation), Nídia Aparecida Hernandes(Local Initiatives Support Corporation), Katy Mitchell(Local Initiatives Support Corporation), Catherine J. Hill(Local Initiatives Support Corporation), Annemarie L. Lee(Local Initiatives Support Corporation), Carlos Augusto Camillo(Local Initiatives Support Corporation), Thierry Troosters(Local Initiatives Support Corporation), Martijn A. Spruit(Local Initiatives Support Corporation), Brian Carlin(Local Initiatives Support Corporation), Jack Wanger(Local Initiatives Support Corporation), Véronique Pepin(Local Initiatives Support Corporation), Didier Saey(Local Initiatives Support Corporation), Fábio Pitta(Local Initiatives Support Corporation), David A. Kaminsky(Local Initiatives Support Corporation), Meredith C. McCormack(Local Initiatives Support Corporation), Neil R. MacIntyre(Local Initiatives Support Corporation), Bruce H. Culver(Local Initiatives Support Corporation), Frank C. Sciurba(Local Initiatives Support Corporation), Susan M. Revill(Local Initiatives Support Corporation), Veronica Delafosse(Local Initiatives Support Corporation), Anne E. Holland(Local Initiatives Support Corporation)
European Respiratory Journal
October 30, 2014
Cited by 932Open Access
Full Text

Abstract

This systematic review examined the measurement properties of the 6-min walk test (6MWT), incremental shuttle walk test (ISWT) and endurance shuttle walk test (ESWT) in adults with chronic respiratory disease. Studies that report the evaluation or use of the 6MWT, ISWT or ESWT were included. We searched electronic databases for studies published between January 2000 and September 2013. The 6-min walking distance (6MWD) is a reliable measure (intra-class correlation coefficients ranged from 0.82 to 0.99 in seven studies). There is a learning effect, with greater distance walked on the second test (pooled mean improvement of 26 m in 13 studies). Reliability was similar for ISWT and ESWT, with a learning effect also evident for ISWT (pooled mean improvement of 20 m in six studies). The 6MWD correlates more strongly with peak work capacity (r=0.59-0.93) and physical activity (r=0.40-0.85) than with respiratory function (r=0.10-0.59). Methodological factors affecting 6MWD include track length, encouragement, supplemental oxygen and walking aids. Supplemental oxygen also affects ISWT and ESWT performance. Responsiveness was moderate to high for all tests, with greater responsiveness to interventions that included exercise training. The findings of this review demonstrate that the 6MWT, ISWT and ESWT are robust tests of functional exercise capacity in adults with chronic respiratory disease.


Related Papers

No related papers found

Powered by citation graph analysis