S

Susan M. Revill

Local Initiatives Support Corporation

Publishes on Chronic Obstructive Pulmonary Disease (COPD) Research, Asthma and respiratory diseases, Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis. 4 papers and 4.4k citations.

4Publications
4.4kTotal Citations

Is this you? Claim your profile.

Add your photo, update your bio, and get notified when your ranking changes.

Top publicationsby citations

An official European Respiratory Society/American Thoracic Society technical standard: field walking tests in chronic respiratory disease
Anne E. Holland, Martijn A. Spruit, Thierry Troosters et al.|European Respiratory Journal|2014
Cited by 2.4kOpen Access

Field walking tests are commonly employed to evaluate exercise capacity, assess prognosis and evaluate treatment response in chronic respiratory diseases. In recent years, there has been a wealth of new literature pertinent to the conduct of the 6-min walk test (6MWT), and a growing evidence base describing the incremental and endurance shuttle walk tests (ISWT and ESWT, respectively). The aim of this document is to describe the standard operating procedures for the 6MWT, ISWT and ESWT, which can be consistently employed by clinicians and researchers. The Technical Standard was developed by a multidisciplinary and international group of clinicians and researchers with expertise in the application of field walking tests. The procedures are underpinned by a concurrent systematic review of literature relevant to measurement properties and test conduct in adults with chronic respiratory disease. Current data confirm that the 6MWT, ISWT and ESWT are valid, reliable and responsive to change with some interventions. However, results are sensitive to small changes in methodology. It is important that two tests are conducted for the 6MWT and ISWT. This Technical Standard for field walking tests reflects current evidence regarding procedures that should be used to achieve robust results.

Dynamic Hyperinflation and Exercise Intolerance in Chronic Obstructive Pulmonary Disease
Denis E. O’Donnell, Susan M. Revill, Katherine A. Webb|American Journal of Respiratory and Critical Care Medicine|2001
Cited by 1.1k

The role of dynamic hyperinflation (DH) in exercise limitation in chronic obstructive pulmonary disease (COPD) remains to be defined. We examined DH during exercise in 105 patients with COPD (FEV(1) = 37 +/- 13% predicted; mean +/- SD) and studied the relationships between resting lung volumes, DH during exercise, and peak oxygen consumption (VO(2)). Patients completed pulmonary function tests and incremental cycle exercise tests. We measured the change in inspiratory capacity (Delta IC) during exercise to reflect changes in DH. During exercise, 80% of patients showed significant DH above resting values. IC decreased 0.37 +/- 0.39 L or 14 +/- 15% predicted during exercise (p < 0.0005), but with large variation in range. Delta IC correlated best with resting IC, both expressed %predicted (r = -0.50, p < 0.0005). Peak VO(2) (%predicted maximum) correlated best with the peak tidal volume attained (VT standardized as % of predicted vital capacity) (r = 0.68, p < 0.0005), which, in turn, correlated strongly with IC at peak exercise (r = 0.79, p < 0.0005) or at rest (r = 0.75, p < 0.0005). The extent of DH during exercise in COPD correlated best with resting IC. DH curtailed the VT response to exercise. This inability to expand VT in response to increasing metabolic demand contributed importantly to exercise intolerance in COPD.

An official systematic review of the European Respiratory Society/American Thoracic Society: measurement properties of field walking tests in chronic respiratory disease
Sally Singh, Milo A. Puhan, Vasileios Andrianopoulos et al.|European Respiratory Journal|2014
Cited by 932Open Access

This systematic review examined the measurement properties of the 6-min walk test (6MWT), incremental shuttle walk test (ISWT) and endurance shuttle walk test (ESWT) in adults with chronic respiratory disease. Studies that report the evaluation or use of the 6MWT, ISWT or ESWT were included. We searched electronic databases for studies published between January 2000 and September 2013. The 6-min walking distance (6MWD) is a reliable measure (intra-class correlation coefficients ranged from 0.82 to 0.99 in seven studies). There is a learning effect, with greater distance walked on the second test (pooled mean improvement of 26 m in 13 studies). Reliability was similar for ISWT and ESWT, with a learning effect also evident for ISWT (pooled mean improvement of 20 m in six studies). The 6MWD correlates more strongly with peak work capacity (r=0.59-0.93) and physical activity (r=0.40-0.85) than with respiratory function (r=0.10-0.59). Methodological factors affecting 6MWD include track length, encouragement, supplemental oxygen and walking aids. Supplemental oxygen also affects ISWT and ESWT performance. Responsiveness was moderate to high for all tests, with greater responsiveness to interventions that included exercise training. The findings of this review demonstrate that the 6MWT, ISWT and ESWT are robust tests of functional exercise capacity in adults with chronic respiratory disease.