Standardization of Spirometry 2019 Update. An Official American Thoracic Society and European Respiratory Society Technical StatementBrian L. Graham, Irene Steenbruggen, Martin R. Miller et al.|American Journal of Respiratory and Critical Care Medicine|2019 Abstract Background Spirometry is the most common pulmonary function test. It is widely used in the assessment of lung function to provide objective information used in the diagnosis of lung diseases and monitoring lung health. In 2005, the American Thoracic Society and the European Respiratory Society jointly adopted technical standards for conducting spirometry. Improvements in instrumentation and computational capabilities, together with new research studies and enhanced quality assurance approaches, have led to the need to update the 2005 technical standards for spirometry to take full advantage of current technical capabilities. Methods This spirometry technical standards document was developed by an international joint task force, appointed by the American Thoracic Society and the European Respiratory Society, with expertise in conducting and analyzing pulmonary function tests, laboratory quality assurance, and developing international standards. A comprehensive review of published evidence was performed. A patient survey was developed to capture patients’ experiences. Results Revisions to the 2005 technical standards for spirometry were made, including the addition of factors that were not previously considered. Evidence to support the revisions was cited when applicable. The experience and expertise of task force members were used to develop recommended best practices. Conclusions Standards and consensus recommendations are presented for manufacturers, clinicians, operators, and researchers with the aims of increasing the accuracy, precision, and quality of spirometric measurements and improving the patient experience. A comprehensive guide to aid in the implementation of these standards was developed as an online supplement.
An official European Respiratory Society/American Thoracic Society technical standard: field walking tests in chronic respiratory diseaseField walking tests are commonly employed to evaluate exercise capacity, assess prognosis and evaluate treatment response in chronic respiratory diseases. In recent years, there has been a wealth of new literature pertinent to the conduct of the 6-min walk test (6MWT), and a growing evidence base describing the incremental and endurance shuttle walk tests (ISWT and ESWT, respectively). The aim of this document is to describe the standard operating procedures for the 6MWT, ISWT and ESWT, which can be consistently employed by clinicians and researchers. The Technical Standard was developed by a multidisciplinary and international group of clinicians and researchers with expertise in the application of field walking tests. The procedures are underpinned by a concurrent systematic review of literature relevant to measurement properties and test conduct in adults with chronic respiratory disease. Current data confirm that the 6MWT, ISWT and ESWT are valid, reliable and responsive to change with some interventions. However, results are sensitive to small changes in methodology. It is important that two tests are conducted for the 6MWT and ISWT. This Technical Standard for field walking tests reflects current evidence regarding procedures that should be used to achieve robust results.
ERS/ATS technical standard on interpretive strategies for routine lung function testsBACKGROUND: Appropriate interpretation of pulmonary function tests (PFTs) involves the classification of observed values as within/outside the normal range based on a reference population of healthy individuals, integrating knowledge of physiological determinants of test results into functional classifications and integrating patterns with other clinical data to estimate prognosis. In 2005, the American Thoracic Society (ATS) and European Respiratory Society (ERS) jointly adopted technical standards for the interpretation of PFTs. We aimed to update the 2005 recommendations and incorporate evidence from recent literature to establish new standards for PFT interpretation. METHODS: This technical standards document was developed by an international joint Task Force, appointed by the ERS/ATS with multidisciplinary expertise in conducting and interpreting PFTs and developing international standards. A comprehensive literature review was conducted and published evidence was reviewed. RESULTS: Recommendations for the choice of reference equations and limits of normal of the healthy population to identify individuals with unusually low or high results are discussed. Interpretation strategies for bronchodilator responsiveness testing, limits of natural changes over time and severity are also updated. Interpretation of measurements made by spirometry, lung volumes and gas transfer are described as they relate to underlying pathophysiology with updated classification protocols of common impairments. CONCLUSIONS: Interpretation of PFTs must be complemented with clinical expertise and consideration of the inherent biological variability of the test and the uncertainty of the test result to ensure appropriate interpretation of an individual's lung function measurements.
An official systematic review of the European Respiratory Society/American Thoracic Society: measurement properties of field walking tests in chronic respiratory diseaseThis systematic review examined the measurement properties of the 6-min walk test (6MWT), incremental shuttle walk test (ISWT) and endurance shuttle walk test (ESWT) in adults with chronic respiratory disease. Studies that report the evaluation or use of the 6MWT, ISWT or ESWT were included. We searched electronic databases for studies published between January 2000 and September 2013. The 6-min walking distance (6MWD) is a reliable measure (intra-class correlation coefficients ranged from 0.82 to 0.99 in seven studies). There is a learning effect, with greater distance walked on the second test (pooled mean improvement of 26 m in 13 studies). Reliability was similar for ISWT and ESWT, with a learning effect also evident for ISWT (pooled mean improvement of 20 m in six studies). The 6MWD correlates more strongly with peak work capacity (r=0.59-0.93) and physical activity (r=0.40-0.85) than with respiratory function (r=0.10-0.59). Methodological factors affecting 6MWD include track length, encouragement, supplemental oxygen and walking aids. Supplemental oxygen also affects ISWT and ESWT performance. Responsiveness was moderate to high for all tests, with greater responsiveness to interventions that included exercise training. The findings of this review demonstrate that the 6MWT, ISWT and ESWT are robust tests of functional exercise capacity in adults with chronic respiratory disease.
Technical standards for respiratory oscillometryOscillometry (also known as the forced oscillation technique) measures the mechanical properties of the respiratory system (upper and intrathoracic airways, lung tissue and chest wall) during quiet tidal breathing, by the application of an oscillating pressure signal (input or forcing signal), most commonly at the mouth. With increased clinical and research use, it is critical that all technical details of the hardware design, signal processing and analyses, and testing protocols are transparent and clearly reported to allow standardisation, comparison and replication of clinical and research studies. Because of this need, an update of the 2003 European Respiratory Society (ERS) technical standards document was produced by an ERS task force of experts who are active in clinical oscillometry research. The aim of the task force was to provide technical recommendations regarding oscillometry measurement including hardware, software, testing protocols and quality control. The main changes in this update, compared with the 2003 ERS task force document are 1) new quality control procedures which reflect use of “within-breath” analysis, and methods of handling artefacts; 2) recommendation to disclose signal processing, quality control, artefact handling and breathing protocols ( e.g. number and duration of acquisitions) in reports and publications to allow comparability and replication between devices and laboratories; 3) a summary review of new data to support threshold values for bronchodilator and bronchial challenge tests; and 4) updated list of predicted impedance values in adults and children.