V

Vellaiyan Subramani

DR. B.R.A. Institute Rotary Cancer Hospital

Publishes on Advanced Radiotherapy Techniques, Endometrial and Cervical Cancer Treatments, Radiation Therapy and Dosimetry. 31 papers and 602 citations.

31Publications
602Total Citations

Is this you? Claim your profile.

Add your photo, update your bio, and get notified when your ranking changes.

Top publicationsby citations

Use of transrectal ultrasound for high dose rate interstitial brachytherapy for patients of carcinoma of uterine cervix
Daya Nand Sharma, Goura Kisor Rath, Sanjay Thulkar et al.|Journal of Gynecologic Oncology|2010
Cited by 62Open Access

OBJECTIVE: Transrectal ultrasound (TRUS) has been widely used for guiding prostate implants, but not much for interstitial brachytherapy (IBT) of cervix cancer. The aim of our study is to report our experience with TRUS guided high dose rate (HDR) IBT in patients with carcinoma of uterine cervix. METHODS: During the year 2005-2006, 25 patients of cervical cancer not suitable for intracavitary radiotherapy (ICRT), were enrolled in this prospective study. We used B-K Medical USG machine (Falcon 2101) equipped with a TRUS probe (8658) having a transducer of 7.5 MHz for IBT. Post procedure, a CT scan was done for verification of needle position and treatment planning. Two weekly sessions of HDR IBT of 8-10 Gy each were given after pelvic external beam radiation therapy. RESULTS: A total of 40 IBT procedures were performed in 25 patients. Average duration of implant procedure was 50 minutes. There was no uterine perforation in any of 11 patients in whom central tandem was used. CT scan did not show needle perforation of bladder/rectum in any of the patients. During perioperative period, only 1 procedure (2.5%) was associated with hematuria which stopped within 6 hours. Severe late toxicity was observed in 3 (12%) patients. Overall pelvic control rate was 64%. CONCLUSION: Our experience suggests that TRUS is a practical and effective imaging device for guiding the IBT procedure of cervical cancer patients. It helps in accurate placements of needles thus avoiding the injury to normal pelvic structures.

Low-dose radiation therapy for COVID-19 pneumonia: a pilot study
Daya Nand Sharma, Randeep Guleria, Naveet Wig et al.|British Journal of Radiology|2021
Cited by 47Open Access

OBJECTIVES: The World Health Organization (WHO) has declared coronavirus disease 2019 (COVID-19) as pandemic in March 2020. Currently there is no specific effective treatment for COVID-19. The major cause of death in COVID-19 is severe pneumonia leading to respiratory failure. Radiation in low doses (<100 cGy) has been known for its anti-inflammatory effect and therefore, low dose radiation therapy (LDRT) to lungs can potentially mitigate the severity of pneumonia and reduce mortality. We conducted a pilot trial to study the feasibility and clinical efficacy of LDRT to lungs in the management of patients with COVID-19. METHODS: From June to Aug 2020, we enrolled 10 patients with COVID-19 having moderate to severe risk disease [National Early Warning Score (NEWS) of ≥5]. Patients were treated as per the standard COVID-19 management guidelines along with LDRT to both lungs with a dose of 70cGy in single fraction. Response assessment was done based on the clinical parameters using the NEWS. RESULTS: All patients completed the prescribed treatment. Nine patients had complete clinical recovery mostly within a period ranging from 3 to 7 days. One patient, who was a known hypertensive, showed clinical deterioration and died 24 days after LDRT. No patients showed the signs of acute radiation toxicity. CONCLUSION: The results of our pilot study suggest that LDRT is feasible in COVID-19 patients having moderate to severe disease. Its clinical efficacy may be tested by conducting randomized controlled trials. ADVANCES IN KNOWLEDGE: LDRT has shown promising results in COVID-19 pneumonia and should be researched further through randomized controlled trials.

Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans
Cited by 39Open Access

Abstract Background The accuracy of the two dose calculation engines available for RapidArc planning (both released for clinical use) is investigated in comparison to the COMPASS data. Methods Two dose calculation algorithms (Acuros-XB and Anisotropic Analytic Algorithm (AAA)) were used to calculate RA plans and compared to calculations with the Collapsed Cone Convolution algorithm (CC) from the COMPASS system (IBA Dosimetry). CC calculations, performed on patient data, are based on experimental fluence measurements with a 2D array of ion chambers mounted on the linac head. The study was conducted on clinical cases treated with RA. Five cases for each of the following groups were included: Brain, Head and Neck, Thorax, Pelvis and stereotactic body radiation therapy for hypo-fractionated treatments with small fields. COMPASS measurements were performed with the iMatrixx-2D array. RapidArc plans were optimized for delivery using 6MV photons from a Clinac-iX (Varian, Palo Alto, USA). Accuracy of the RA calculation was appraised by means of: 1) comparison of Dose Volume histograms (DVH) metrics; 2) analysis of differential dose distributions and determination of mean dose differences per organ; 3) 3D gamma analysis with distance-to-agreement and dose difference thresholds set to 3%/3 mm or 2%/2 mm for targets, organs at risks and for the volumes encompassed by the 50 and 10% isodoses. Results For almost all parameters, the better agreement was between Acuros-XB and COMPASS independently from the anatomical site and fractionation. The same result was obtained from the mean dose difference per organ with Acuros-CC average differences below 0.5% while for AAA-CC data, average deviations exceeded 0.5% and in the case of the pelvis 1%. Relevance of observed differences determined with the 3D gamma analysis resulted in a pass rate exceeding 99.5% for Acuros-CC and exceeding 97.5% for AAA-CC. Conclusions This study demonstrated that i) a good agreement exists between COMPASS-CC calculations based on measured fluences with respect to dose distributions obtained with both Acuros-XB and AAA algorithms; ii) 3D dose distributions reconstructed from actual delivery coincide very precisely with the planned data; iii) a slight preference in favor of Acuros-XB was observed suggesting the preference for this algorithm in clinical applications.

Auto-segmentation of head and neck organs at risk in radiotherapy and its dependence on anatomic similarity
Anantharaman Ayyalusamy, Vellaiyan Subramani, Shanmuga Subramanian et al.|Radiation Oncology Journal|2019
Cited by 35Open Access

PURPOSE: The aim is to study the dependence of deformable based auto-segmentation of head and neck organs-at-risks (OAR) on anatomy matching for a single atlas based system and generate an acceptable set of contours. METHODS: A sample of ten patients in neutral neck position and three atlas sets consisting of ten patients each in different head and neck positions were utilized to generate three scenarios representing poor, average and perfect anatomy matching respectively and auto-segmentation was carried out for each scenario. Brainstem, larynx, mandible, cervical oesophagus, oral cavity, pharyngeal muscles, parotids, spinal cord, and trachea were the structures selected for the study. Automatic and oncologist reference contours were compared using the dice similarity index (DSI), Hausdroff distance and variation in the centre of mass (COM). RESULTS: The mean DSI scores for brainstem was good irrespective of the anatomy matching scenarios. The scores for mandible, oral cavity, larynx, parotids, spinal cord, and trachea were unacceptable with poor matching but improved with enhanced bony matching whereas cervical oesophagus and pharyngeal muscles had less than acceptable scores for even perfect matching scenario. HD value and variation in COM decreased with better matching for all the structures. CONCLUSION: Improved anatomy matching resulted in better segmentation. At least a similar setup can help generate an acceptable set of automatic contours in systems employing single atlas method. Automatic contours from average matching scenario were acceptable for most structures. Importance should be given to head and neck position during atlas generation for a single atlas based system.