Individualized 3D printed navigation template-assisted atlantoaxial pedicle screws vs. free-hand screws for the treatment of upper cervical fractures

Guoqi Niu(The Second Affiliated Hospital of Bengbu Medical College), Jiawei Cheng(The Second Affiliated Hospital of Bengbu Medical College), Lutan Liu(The Second Affiliated Hospital of Bengbu Medical College), Chao Li(The Second Affiliated Hospital of Bengbu Medical College), Gong Zhou(The Second Affiliated Hospital of Bengbu Medical College), Hui Chen(The Second Affiliated Hospital of Bengbu Medical College), Tao Liu(The Second Affiliated Hospital of Bengbu Medical College), Hu Nie(The Second Affiliated Hospital of Bengbu Medical College), Zheng Sun(The Second Affiliated Hospital of Bengbu Medical College), Weili Jiang(The Second Affiliated Hospital of Bengbu Medical College), Qiankun Zhou(The Second Affiliated Hospital of Bengbu Medical College), Baoyin Zhao(The Second Affiliated Hospital of Bengbu Medical College), Jun Zhu(The Second Affiliated Hospital of Bengbu Medical College), Ruochen Yu(The Second Affiliated Hospital of Bengbu Medical College), Ya‐Long Guo(The Second Affiliated Hospital of Bengbu Medical College), Yi Yang(The Second Affiliated Hospital of Bengbu Medical College), Jianzhong Bai(The Second Affiliated Hospital of Bengbu Medical College)
Frontiers in Surgery
September 26, 2022
Cited by 13Open Access
Full Text

Abstract

Objective This study aims to compare the efficacy and safety of freehand atlantoaxial pedicle screws against custom 3D printed navigation template screws in the treatment of upper cervical fractures. Methods In our institution from 2010 to 2020, a retrospective cohort analysis of 23 patients with upper cervical fractures was done. These patients were separated into two groups: group A ( N = 12), which received customized 3D printed navigation template-assisted screws with virtual reality techniques, and group B ( N = 11), which received freehand screws assisted by intraoperative fluoroscopy. Every patient was monitored for more than 1 year. The two groups were contrasted in terms of screw implant accuracy, cervical spine Japanese Orthopaedic Association (JOA) score, American Spinal Injury Association (ASIA) score, visual analogue scale (VAS) score, surgical time, fluoroscopy times, and intraoperative blood loss. Results A total of 88 atlantoaxial pedicle screws in all, 46 in group A and 42 in group B, were implanted. In group A, the screw insertion accuracy rate was 95.7%, compared to 80.0% in group B ( P < 0.05). When compared to group B, group A had shorter surgery times, less blood loss, fewer fluoroscopies, a higher short-term JOA score, and overt pain reduction ( P < 0.05). However, there was no discernible difference between the two groups' VAS scores, long-term JOA scores, or ASIA scores (sensory and motor), at the most recent follow-up. Conclusion Individualized 3D printed guide leads to significant improvement in the screw safety, efficacy, and accuracy, which may be a promising strategy for the treatment of upper cervical fractures.


Related Papers

No related papers found

Powered by citation graph analysis