Relationship between Anti-Spike Protein Antibody Titers and SARS-CoV-2 <i>In Vitro</i> Virus Neutralization in Convalescent Plasma

Eric Salazar(Cornell University), Suresh V. Kuchipudi(Pennsylvania State University), Paul A. Christensen(Methodist Hospital), Todd N. Eagar(Cornell University), Yi Xin(Cornell University), Picheng Zhao(Methodist Hospital), Zhicheng Jin(Methodist Hospital), Sheng Long(Houston Methodist), Randall J. Olsen(Houston Methodist), Jian Chen(Cornell University), Brian Castillo(Cornell University), Christopher Leveque(Cornell University), Dalton M. Towers(The University of Texas at Austin), Jason J. Lavinder(The University of Texas at Austin), Jimmy Gollihar, José Cardona, Gregory C. Ippolito(The University of Texas at Austin), Ruth H. Nissly(Pennsylvania State University), Ian M. Bird(Pennsylvania State University), Denver Greenawalt(Pennsylvania State University), Randall M. Rossi(Pennsylvania State University), Abinhay Gontu(Pennsylvania State University), Sreenidhi Srinivasan(Pennsylvania State University), Indira Poojary(Pennsylvania State University), Isabella M. Cattadori(Houston Methodist), Peter J. Hudson(Pennsylvania State University), Nicole Joselyn(United States Army Medical Research Institute of Infectious Diseases), Laura I. Prugar(United States Army Medical Research Institute of Infectious Diseases), Kathleen E. Huie(United States Army Medical Research Institute of Infectious Diseases), Andrew S. Herbert(United States Army Medical Research Institute of Infectious Diseases), David W. Bernard(Cornell University), John M. Dye(United States Army Medical Research Institute of Infectious Diseases), Vivek Kapur(Pennsylvania State University), James M. Musser(Houston Methodist)
bioRxiv (Cold Spring Harbor Laboratory)
June 9, 2020
Cited by 71Open Access
Full Text

Abstract

Abstract Newly emerged pathogens such as SARS-CoV-2 highlight the urgent need for assays that detect levels of neutralizing antibodies that may be protective. We studied the relationship between anti-spike ectodomain (ECD) and anti-receptor binding domain (RBD) IgG titers, and SARS-CoV-2 virus neutralization (VN) titers generated by two different in vitro assays using convalescent plasma samples obtained from 68 COVID-19 patients, including 13 who donated plasma multiple times. Only 23% (16/68) of donors had been hospitalized. We also studied 16 samples from subjects found to have anti-spike protein IgG during surveillance screening of asymptomatic individuals. We report a strong positive correlation between both plasma anti-RBD and anti-ECD IgG titers, and in vitro VN titer. Anti-RBD plasma IgG correlated slightly better than anti-ECD IgG titer with VN titer. The probability of a VN titer ≥160 was 80% or greater with anti-RBD or anti-ECD titers of ≥1:1350. Thirty-seven percent (25/68) of convalescent plasma donors lacked VN titers ≥160, the FDA-recommended level for convalescent plasma used for COVID-19 treatment. Dyspnea, hospitalization, and disease severity were significantly associated with higher VN titer. Frequent donation of convalescent plasma did not significantly decrease either VN or IgG titers. Analysis of 2,814 asymptomatic adults found 27 individuals with anti-RBD or anti-ECD IgG titers of ≥1:1350, and evidence of VN ≥1:160. Taken together, we conclude that anti-RBD or anti-ECD IgG titers can serve as a surrogate for VN titers to identify suitable plasma donors. Plasma anti-RBD or anti-ECD titer of ≥1:1350 may provide critical information about protection against COVID-19 disease.


Related Papers

No related papers found

Powered by citation graph analysis