A 1.4-m $\Omega$ -Sensitivity 94-dB Dynamic-Range Electrical Impedance Tomography SoC and 48-Channel Hub-SoC for 3-D Lung Ventilation Monitoring System

Minseo Kim(Korea Advanced Institute of Science and Technology), Jaeeun Jang(Korea Advanced Institute of Science and Technology), Hyunki Kim(Korea Advanced Institute of Science and Technology), Ji Hee Lee(Korea Advanced Institute of Science and Technology), Jae-hyuck Lee(Korea Advanced Institute of Science and Technology), Jiwon Lee(Korea Advanced Institute of Science and Technology), Kyoung-Rog Lee(Korea Advanced Institute of Science and Technology), Kwantae Kim(Korea Advanced Institute of Science and Technology), Yongsu Lee(Korea Advanced Institute of Science and Technology), Kyuho Lee(Korea Advanced Institute of Science and Technology), Hoi‐Jun Yoo(Korea Advanced Institute of Science and Technology)
IEEE Journal of Solid-State Circuits
October 3, 2017
Cited by 63

Abstract

A wearable electrical impedance tomography (EIT) system is proposed for the portable real-time 3-D lung ventilation monitoring. It consists of two types of SoCs, active electrode (AE)-SoC and Hub-SoC, mounted on wearable belts. The 48-channel AE-SoCs are integrated on flexible printed circuit board belt, and Hub-SoC is integrated in the hub module which performs data gathering and wireless communication between an external imaging device. To get high accuracy under the variation of conductivity, the dual-mode current stimulator provides the optimal frequency for time difference-EIT and frequency difference-EIT with simultaneous 4 k–128 kHz impedance sensing. A wide dynamic range instruments amplifier is proposed to provide 94 dB of wide dynamic range impedance sensing. In addition, the 48-channel AE system with the dedicated communication and calibration is implemented to achieve 1.4- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text{m}\Omega $ </tex-math></inline-formula> sensitivity of impedance difference in the in vivo environment. The AE-/Hub-SoCs occupy 3.2 and 1.3 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> in 65-nm CMOS technology and consume <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$124~\mu \text{W}$ </tex-math></inline-formula> and 1.1 mW with 1.2 V supply, respectively. As a result, EIT images are reconstructed with 90% of accuracy, and up to 10 frames/s real-time 3-D lung images are successfully displayed.


Related Papers

No related papers found

Powered by citation graph analysis