An Intervention to Decrease Catheter-Related Bloodstream Infections in the ICUBACKGROUND: Catheter-related bloodstream infections occurring in the intensive care unit (ICU) are common, costly, and potentially lethal. METHODS: We conducted a collaborative cohort study predominantly in ICUs in Michigan. An evidence-based intervention was used to reduce the incidence of catheter-related bloodstream infections. Multilevel Poisson regression modeling was used to compare infection rates before, during, and up to 18 months after implementation of the study intervention. Rates of infection per 1000 catheter-days were measured at 3-month intervals, according to the guidelines of the National Nosocomial Infections Surveillance System. RESULTS: A total of 108 ICUs agreed to participate in the study, and 103 reported data. The analysis included 1981 ICU-months of data and 375,757 catheter-days. The median rate of catheter-related bloodstream infection per 1000 catheter-days decreased from 2.7 infections at baseline to 0 at 3 months after implementation of the study intervention (P< or =0.002), and the mean rate per 1000 catheter-days decreased from 7.7 at baseline to 1.4 at 16 to 18 months of follow-up (P<0.002). The regression model showed a significant decrease in infection rates from baseline, with incidence-rate ratios continuously decreasing from 0.62 (95% confidence interval [CI], 0.47 to 0.81) at 0 to 3 months after implementation of the intervention to 0.34 (95% CI, 0.23 to 0.50) at 16 to 18 months. CONCLUSIONS: An evidence-based intervention resulted in a large and sustained reduction (up to 66%) in rates of catheter-related bloodstream infection that was maintained throughout the 18-month study period.
Eliminating catheter-related bloodstream infections in the intensive care unit*OBJECTIVE: To determine whether a multifaceted systems intervention would eliminate catheter-related bloodstream infections (CR-BSIs). DESIGN: Prospective cohort study in a surgical intensive care unit (ICU) with a concurrent control ICU. SETTING: The Johns Hopkins Hospital. PATIENTS: All patients with a central venous catheter in the ICU. INTERVENTION: To eliminate CR-BSIs, a quality improvement team implemented five interventions: educating the staff; creating a catheter insertion cart; asking providers daily whether catheters could be removed; implementing a checklist to ensure adherence to evidence-based guidelines for preventing CR-BSIs; and empowering nurses to stop the catheter insertion procedure if a violation of the guidelines was observed. MEASUREMENT: The primary outcome variable was the rate of CR-BSIs per 1,000 catheter days from January 1, 1998, through December 31, 2002. Secondary outcome variables included adherence to evidence-based infection control guidelines during catheter insertion. MAIN RESULTS: Before the intervention, we found that physicians followed infection control guidelines during 62% of the procedures. During the intervention time period, the CR-BSI rate in the study ICU decreased from 11.3/1,000 catheter days in the first quarter of 1998 to 0/1,000 catheter days in the fourth quarter of 2002. The CR-BSI rate in the control ICU was 5.7/1,000 catheter days in the first quarter of 1998 and 1.6/1,000 catheter days in the fourth quarter of 2002 (p = .56). We estimate that these interventions may have prevented 43 CR-BSIs, eight deaths, and 1,945,922 dollars in additional costs per year in the study ICU. CONCLUSIONS: Multifaceted interventions that helped to ensure adherence with evidence-based infection control guidelines nearly eliminated CR-BSIs in our surgical ICU.