High-Resolution Genotyping by Amplicon Melting Analysis Using LCGreenBACKGROUND: High-resolution amplicon melting analysis was recently introduced as a closed-tube method for genotyping and mutation scanning (Gundry et al. Clin Chem 2003;49:396-406). The technique required a fluorescently labeled primer and was limited to the detection of mutations residing in the melting domain of the labeled primer. Our aim was to develop a closed-tube system for genotyping and mutation scanning that did not require labeled oligonucleotides. METHODS: We studied polymorphisms in the hydroxytryptamine receptor 2A (HTR2A) gene (T102C), beta-globin (hemoglobins S and C) gene, and cystic fibrosis (F508del, F508C, I507del) gene. PCR was performed in the presence of the double-stranded DNA dye LCGreen, and high-resolution amplicon melting curves were obtained. After fluorescence normalization, temperature adjustment, and/or difference analysis, sequence alterations were distinguished by curve shape and/or position. Heterozygous DNA was identified by the low-temperature melting of heteroduplexes not observed with other dyes commonly used in real-time PCR. RESULTS: The six common beta-globin genotypes (AA, AS, AC, SS, CC, and SC) were all distinguished in a 110-bp amplicon. The HTR2A single-nucleotide polymorphism was genotyped in a 544-bp fragment that split into two melting domains. Because melting curve acquisition required only 1-2 min, amplification and analysis were achieved in 10-20 min with rapid cycling conditions. CONCLUSIONS: High-resolution melting analysis of PCR products amplified in the presence of LCGreen can identify both heterozygous and homozygous sequence variants. The technique requires only the usual unlabeled primers and a generic double-stranded DNA dye added before PCR for amplicon genotyping, and is a promising method for mutation screening.
Amplicon Melting Analysis with Labeled Primers: A Closed-Tube Method for Differentiating Homozygotes and HeterozygotesBACKGROUND: Common methods for identification of DNA sequence variants use gel electrophoresis or column separation after PCR. METHODS: We developed a method for sequence variant analysis requiring only PCR and amplicon melting analysis. One of the PCR primers was fluorescently labeled. After PCR, the melting transition of the amplicon was monitored by high-resolution melting analysis. Different homozygotes were distinguished by amplicon melting temperature (T(m)). Heterozygotes were identified by low-temperature melting of heteroduplexes, which broadened the overall melting transition. In both cases, melting analysis required approximately 1 min and no sample processing was needed after PCR. RESULTS: Polymorphisms in the HTR2A (T102C), beta-globin [hemoglobin (Hb) S, C, and E], and cystic fibrosis (F508del, F508C, I507del, I506V) genes were analyzed. Heteroduplexes produced by amplification of heterozygous DNA were best detected by rapid cooling (>2 degrees C/s) of denatured products, followed by rapid heating during melting analysis (0.2-0.4 degrees C/s). Heterozygotes were distinguished from homozygotes by a broader melting transition, and each heterozygote had a uniquely shaped fluorescent melting curve. All homozygotes tested were distinguished from each other, including Hb AA and Hb SS, which differed in T(m) by <0.2 degrees C. The amplicons varied in length from 44 to 304 bp. In place of one labeled and one unlabeled primer, a generic fluorescent oligonucleotide could be used if a 5' tail of identical sequence was added to one of the two unlabeled primers. CONCLUSION: High-resolution melting analysis of PCR products amplified with labeled primers can identify both heterozygous and homozygous sequence variants.
Real-Time Multiplex PCR AssaysBase-pair neutral homozygotes can be discriminated by calibrated high-resolution melting of small ampliconsGenotyping by high-resolution melting analysis of small amplicons is homogeneous and simple. However, this approach can be limited by physical and chemical components of the system that contribute to intersample melting variation. It is challenging for this method to distinguish homozygous G::C from C::G or A::T from T::A base-pair neutral variants, which comprise approximately 16% of all human single nucleotide polymorphisms (SNPs). We used internal oligonucleotide calibrators and custom analysis software to improve small amplicon (42-86 bp) genotyping on the LightScanner. Three G/C (PAH c.1155C>G, CHK2 c.1-3850G>C and candidate gene BX647987 c.261+22,290C>G) and three T/A (CPS1 c.3405-29A>T, OTC c.299-8T>A and MSH2 c.1511-9A>T) human single nucleotide variants were analyzed. Calibration improved homozygote genotyping accuracy from 91.7 to 99.7% across 1105 amplicons from 141 samples for five of the six targets. The average T(m) standard deviations of these targets decreased from 0.067 degrees C before calibration to 0.022 degrees C after calibration. We were unable to generate a small amplicon that could discriminate the BX647987 c.261+22,290C>G (rs1869458) SNP, despite reducing standard deviations from 0.086 degrees C to 0.032 degrees C. Two of the sites contained symmetric nearest neighbors adjacent to the SNPs. Unexpectedly, we were able to distinguish these homozygotes by T(m) even though current nearest neighbor models predict that the two homozygous alleles would be identical.
Rapid <i>F508del</i> and <i>F508C</i> Assay Using Fluorescent Hybridization ProbesAmplification and fluorescent genotyping of the cystic fibrosis F508del locus was achieved from human genomic DNA in less than 30 min. The hybridization of adjacent fluorescent probes at the mutation site was monitored by resonance energy transfer between fluorescein and Cy5 during heating or cooling. Characteristic curves were obtained for each genotype; the first derivative of these fluorescent curves has a maximum at an apparent hybridization temperature (Tm) that is specific for each probe/allele duplex. The direction and rate of temperature change determines the difference between the apparent Tm and the true equilibrium Tm. One hundred and five sample were genotyped for the F508del cystic fibrosis mutation by heating and cooling curve profiles. These genotypes were validated by allele-specific amplification. Two fluorescein hybridization probes were designed to match the wild-type sequence perfectly from either codons 502 to 513 or from 504 to 511 on the cystic fibrosis transconductance regulator gene of chromosome 7. While genotyping for the F508del, an allele with the F508C base change was detected. For both F508del and F508C variants, the Tm shift from wild type was greater with a 24-mer probe than with a 35-mer probe. Fluorescent monitoring of hybridization probes is a versatile technique that can detect unexpected sequence alterations.