Goethe University Frankfurt
Publishes on Advanced X-ray and CT Imaging, Radiation Dose and Imaging, Medical Imaging Techniques and Applications. 657 papers and 19.1k citations.
Add your photo, update your bio, and get notified when your ranking changes.
Introduction of slip-ring technology with subsequent development of single- and multi-detector row helical computed tomographic (CT) scanners have expanded the applications of CT, leading to a substantial increase in the number of CT examinations being performed. Owing to concerns about the resultant increase in associated radiation dose, many technical innovations have been introduced. One such innovation is automatic tube current modulation. The purpose of automatic tube current modulation is to maintain constant image quality regardless of patient attenuation characteristics, thus allowing radiation dose to patients to be reduced. This review discusses the principles, clinical use, and limitations of different automatic tube current modulation techniques.
PURPOSE: While modern clinical CT scanners under normal circumstances produce high quality images, severe artifacts degrade the image quality and the diagnostic value if metal prostheses or other metal objects are present in the field of measurement. Standard methods for metal artifact reduction (MAR) replace those parts of the projection data that are affected by metal (the so-called metal trace or metal shadow) by interpolation. However, while sinogram interpolation methods efficiently remove metal artifacts, new artifacts are often introduced, as interpolation cannot completely recover the information from the metal trace. The purpose of this work is to introduce a generalized normalization technique for MAR, allowing for efficient reduction of metal artifacts while adding almost no new ones. The method presented is compared to a standard MAR method, as well as MAR using simple length normalization. METHODS: In the first step, metal is segmented in the image domain by thresholding. A 3D forward projection identifies the metal trace in the original projections. Before interpolation, the projections are normalized based on a 3D forward projection of a prior image. This prior image is obtained, for example, by a multithreshold segmentation of the initial image. The original rawdata are divided by the projection data of the prior image and, after interpolation, denormalized again. Simulations and measurements are performed to compare normalized metal artifact reduction (NMAR) to standard MAR with linear interpolation and MAR based on simple length normalization. RESULTS: Promising results for clinical spiral cone-beam data are presented in this work. Included are patients with hip prostheses, dental fillings, and spine fixation, which were scanned at pitch values ranging from 0.9 to 3.2. Image quality is improved considerably, particularly for metal implants within bone structures or in their proximity. The improvements are evaluated by comparing profiles through images and sinograms for the different methods and by inspecting ROIs. NMAR outperforms both other methods in all cases. It reduces metal artifacts to a minimum, even close to metal regions. Even for patients with dental fillings, which cause most severe artifacts, satisfactory results are obtained with NMAR. In contrast to other methods, NMAR prevents the usual blurring of structures close to metal implants if the metal artifacts are moderate. CONCLUSIONS: NMAR clearly outperforms the other methods for both moderate and severe artifacts. The proposed method reliably reduces metal artifacts from simulated as well as from clinical CT data. Computationally efficient and inexpensive compared to iterative methods, NMAR can be used as an additional step in any conventional sinogram inpainting-based MAR method.
Background The first clinical CT system to use photon-counting detector (PCD) technology has become available for patient care. Purpose To assess the technical performance of the PCD CT system with use of phantoms and representative participant examinations. Materials and Methods Institutional review board approval and written informed consent from four participants were obtained. Technical performance of a dual-source PCD CT system was measured for standard and high-spatial-resolution (HR) collimations. Noise power spectrum, modulation transfer function, section sensitivity profile, iodine CT number accuracy in virtual monoenergetic images (VMIs), and iodine concentration accuracy were measured. Four participants were enrolled (between May 2021 and August 2021) in this prospective study and scanned using similar or lower radiation doses as their respective clinical examinations performed on the same day using energy-integrating detector (EID) CT. Image quality and findings from the participants’ PCD CT and EID CT examinations were compared. Results All standard technical performance measures met accreditation and regulatory requirements. Relative to filtered back-projection reconstructions, images from iterative reconstruction had lower noise magnitude but preserved noise power spectrum shape and peak frequency. Maximum in-plane spatial resolutions of 125 and 208 µm were measured for HR and standard PCD CT scans, respectively. Minimum values for section sensitivity profile full width at half maximum measurements were 0.34 mm (0.2-mm nominal section thickness) and 0.64 mm (0.4-mm nominal section thickness) for HR and standard PCD CT scans, respectively. In a 120-kV standard PCD CT scan of a 40-cm phantom, VMI iodine CT numbers had a mean percentage error of 5.7%, and iodine concentration had root mean squared error of 0.5 mg/cm3, similar to previously reported values for EID CT. VMIs, iodine maps, and virtual noncontrast images were created for a coronary CT angiogram acquired with 66-msec temporal resolution. Participant PCD CT images showed up to 47% lower noise and/or improved spatial resolution compared with EID CT. Conclusion Technical performance of clinical photon-counting detector (PCD) CT is improved relative to that of a current state-of-the-art CT system. The dual-source PCD geometry facilitated 66-msec temporal resolution multienergy cardiac imaging. Study participant images illustrated the effect of the improved technical performance. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Willemink and Grist in this issue.