Simulation of multiple ion channel block provides improved early prediction of compounds’ clinical torsadogenic riskGary R. Mirams, Yi Cui, Anna Sher et al.|Cardiovascular Research|2011 AIMS: The level of inhibition of the human Ether-à-go-go-related gene (hERG) channel is one of the earliest preclinical markers used to predict the risk of a compound causing Torsade-de-Pointes (TdP) arrhythmias. While avoiding the use of drugs with maximum therapeutic concentrations within 30-fold of their hERG inhibitory concentration 50% (IC(50)) values has been suggested, there are drugs that are exceptions to this rule: hERG inhibitors that do not cause TdP, and drugs that can cause TdP but are not strong hERG inhibitors. In this study, we investigate whether a simulated evaluation of multi-channel effects could be used to improve this early prediction of TdP risk. METHODS AND RESULTS: We collected multiple ion channel data (hERG, Na, L-type Ca) on 31 drugs associated with varied risks of TdP. To integrate the information on multi-channel block, we have performed simulations with a variety of mathematical models of cardiac cells (for rabbit, dog, and human ventricular myocyte models). Drug action is modelled using IC(50) values, and therapeutic drug concentrations to calculate the proportion of blocked channels and the channel conductances are modified accordingly. Various pacing protocols are simulated, and classification analysis is performed to evaluate the predictive power of the models for TdP risk. We find that simulation of action potential duration prolongation, at therapeutic concentrations, provides improved prediction of the TdP risk associated with a compound, above that provided by existing markers. CONCLUSION: The suggested calculations improve the reliability of early cardiac safety assessments, beyond those based solely on a hERG block effect.
A New Method for Detection and Quantification of Heartbeat Parameters in Drosophila, Zebrafish, and Embryonic Mouse HeartsThe genetic basis of heart development is remarkably conserved from Drosophila to mammals, and insights from flies have greatly informed our understanding of vertebrate heart development. Recent evidence suggests that many aspects of heart function are also conserved and the genes involved in heart development also play roles in adult heart function. We have developed a Drosophila heart preparation and movement analysis algorithm that allows quantification of functional parameters. Our methodology combines high-speed optical recording of beating hearts with a robust, semi-automated analysis to accurately detect and quantify, on a beat-to-beat basis, not only heart rate but also diastolic and systolic intervals, systolic and diastolic diameters, percent fractional shortening, contraction wave velocity, and cardiac arrhythmicity. Here, we present a detailed analysis of hearts from adult Drosophila, 2-3-day-old zebrafish larva, and 8-day-old mouse embryos, indicating that our methodology is potentially applicable to an array of biological models. We detect progressive age-related changes in fly hearts as well as subtle but distinct cardiac deficits in Tbx5 heterozygote mutant zebrafish. Our methodology for quantifying cardiac function in these genetically tractable model systems should provide valuable insights into the genetics of heart function.
KCNQ potassium channel mutations cause cardiac arrhythmias in <i>Drosophila</i> that mimic the effects of agingKaren Ocorr, Nick Reeves, Robert Wessells et al.|Proceedings of the National Academy of Sciences|2007 Population profiles of industrialized countries show dramatic increases in cardiovascular disease with age, but the molecular and genetic basis of disease progression has been difficult to study because of the lack of suitable model systems. Our studies of Drosophila show a markedly elevated incidence of cardiac dysfunction and arrhythmias in aging fruit fly hearts and a concomitant decrease in the expression of the Drosophila homolog of human KCNQ1-encoded K(+) channel alpha subunits. In humans, this channel is involved in myocardial repolarization, and alterations in the function of this channel are associated with an increased risk for Torsades des Pointes arrhythmias and sudden death. Hearts from young KCNQ1 mutant fruit flies exhibit prolonged contractions and fibrillations reminiscent of Torsades des Pointes arrhythmias, and they exhibit severely increased susceptibility to pacing-induced cardiac dysfunction at young ages, characteristics that are observed only at advanced ages in WT flies. The fibrillations observed in mutant flies correlate with delayed relaxation of the myocardium, as revealed by increases in the duration of phasic contractions, extracellular field potentials, and in the baseline diastolic tension. These results suggest that K(+) currents, mediated by a KCNQ channel, contribute to the repolarization reserve of fly hearts, ensuring normal excitation-contraction coupling and rhythmical contraction. That arrhythmias in both WT and KCNQ1 mutants become worse as flies age suggests that additional factors are also involved.
Cardiac cell modelling: Observations from the heart of the cardiac physiome projectMartin Fink, Steven Niederer, Elizabeth M. Cherry et al.|Progress in Biophysics and Molecular Biology|2010 Markov models for ion channels: versatility versus identifiability and speedMartin Fink, Denis Noble|Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences|2009 Markov models (MMs) represent a generalization of Hodgkin-Huxley models. They provide a versatile structure for modelling single channel data, gating currents, state-dependent drug interaction data, exchanger and pump dynamics, etc. This paper uses examples from cardiac electrophysiology to discuss aspects related to parameter estimation. (i) Parameter unidentifiability (found in 9 out of 13 of the considered models) results in an inability to determine the correct layout of a model, contradicting the idea that model structure and parameters provide insights into underlying molecular processes. (ii) The information content of experimental voltage step clamp data is discussed, and a short but sufficient protocol for parameter estimation is presented. (iii) MMs have been associated with high computational cost (owing to their large number of state variables), presenting an obstacle for multicellular whole organ simulations as well as parameter estimation. It is shown that the stiffness of models increases computation time more than the number of states. (iv) Algorithms and software programs are provided for steady-state analysis, analytical solutions for voltage steps and numerical derivation of parameter identifiability. The results provide a new standard for ion channel modelling to further the automation of model development, the validation process and the predictive power of these models.