M

Manuel Bardiès

Université Toulouse III - Paul Sabatier

ORCID: 0000-0002-1766-727X

Publishes on Radiopharmaceutical Chemistry and Applications, Medical Imaging Techniques and Applications, Advanced Radiotherapy Techniques. 281 papers and 8.6k citations.

281Publications
8.6kTotal Citations

Is this you? Claim your profile.

Add your photo, update your bio, and get notified when your ranking changes.

Top publicationsby citations

GATE: a simulation toolkit for PET and SPECT
S Jan, G. Santin, D. Strul et al.|Physics in Medicine and Biology|2004
Cited by 2.1kOpen Access

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.

A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications
David Sarrut, Manuel Bardiès, Nicolas Boussion et al.|Medical Physics|2014
Cited by 537Open Access

In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy, and in vivo dose monitoring. Investigations that have been performed using GEANT4 only are also mentioned to illustrate the potential of GATE. The very practical feature of GATE making it easy to model both a treatment and an imaging acquisition within the same framework is emphasized. The computational times associated with several applications are provided to illustrate the practical feasibility of the simulations using current computing facilities.

Relationships between tumor size and curability for uniformly targeted therapy with beta-emitting radionuclides.
Cited by 378

UNLABELLED: Targeted radionuclide therapy is a new form of radiotherapy that differs in some important respects from external beam irradiation. One of the most important differences is due to the finite range of ionizing beta particles emitted as a result of radionuclide disintegration. The effects of particle range have important implications for the curability of tumors. METHODS: We used a mathematical model to examine tumor curability and its relationship to tumor size for 22 beta-emitting radionuclides that may have therapeutic potential. The model assumed a uniform distribution of radionuclide throughout. RESULTS: For targeted radionuclide therapy, the relationship between tumor curability and tumor size is different from that for conventional external beam radiotherapy. With targeted radionuclides, there is an optimal tumor size for cure. Tumors smaller than the optimal size are less vulnerable to irradiation from radionuclides because a substantial proportion of the disintegration energy escapes and is deposited outside the tumor volume. CONCLUSION: We found an optimal tumor size for radiocurability by each of the 22 radionuclides considered. Optimal cure diameters range from less than 1 mm for short-range emitters such as 199Au and 33P to several centimeters for long-range emitters such as 90Y and 188Re. The energy emitted per disintegration may be used to predict optimal cure size for uniform distributions of radionuclide.