Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave DetectorsYang Zhao, N. Aritomi, E. Capocasa et al.|Physical Review Letters|2020 The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo, and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.
Free-space orbital angular momentum division multiplexing with Bessel beamsWe present an apparatus for multiplexing and demultiplexing free-space beams carrying different values of orbital angular momentum (OAM), at a wavelength of 633 nm. We have considered nondiffracting Bessel beams of order from 0 to 3, produced by means of suitable binary-amplitude computer-generated holograms and carrying an OAM per photon directly proportional to the beam order. The effectiveness of the OAM division multiplexing technique has been experimentally verified by monitoring the output ports of a demultiplexing interferometer with rotated Dove prisms in the arms.
Gouy phase shift
in nondiffracting Bessel beamsThe results of a theoretical and experimental investigation of the Gouy effect in Bessel beams are presented. We point out that the peculiar feature of the Bessel beams of being nondiffracting is related to the accumulation of an extra axial phase shift (i.e., the Gouy phase shift) linearly dependent on the propagation distance. The constant spatial rate of variation of the Gouy phase shift is independent of the order of the Bessel beam, while it is a growing function of the transverse component of the angular spectrum wave-vectors, originated by the transverse confinement of the beam. A free-space Mach-Zehnder interferometer has been set-up for measuring the transverse intensity distribution of the interference between holographically-produced finite-aperture Bessel beams of order from zero up to three and a reference Gaussian beam, at a wavelength of 633 nm. The interference patterns have been registered for different propagation distances and show a spatial periodicity, in agreement with the expected period due to the linear increase of the Gouy phase shift of the realized Bessel beams.
Measurement of optical losses in a high-finesse 300 m filter cavity for broadband quantum noise reduction in gravitational-wave detectorsE. Capocasa, Y. Guo, M. Eisenmann et al.|Physical review. D/Physical review. D.|2018 Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency-dependent squeezed vacuum state from the output port of the detector, with the squeeze angle rotated by the reflection off a Fabry-Perot filter cavity. One of the most important parameters limiting the squeezing performance is represented by the optical losses of the filter cavity. We report here the operation of a 300 m filter cavity prototype installed at the National Astronomical Observatory of Japan. The cavity is designed to obtain a rotation of the squeeze angle below 100 Hz. After achieving the resonance of the cavity with a multiwavelength technique, the round trip losses have been measured to be between 50 and 90 ppm. This result demonstrates that with realistic assumptions on the input squeeze factor and the other optical losses, a quantum noise reduction of at least 4 dB in the frequency region dominated by radiation pressure can be achieved.
Higher-order Laguerre-Gauss interferometry for gravitational-wave detectors with<i>in situ</i>mirror defects compensationA. Allocca, Alberto Gatto, M. Tacca et al.|Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D, Particles, fields, gravitation, and cosmology|2015 The use of higher-order Laguerre-Gauss modes has been proposed to decrease the influence of thermal noise in future generation gravitational-wave interferometric detectors. The main obstacle for their implementation is the degeneracy of modes with same order, which highly increases the requirements on the mirror defects, beyond the state-of-the-art polishing and coating techniques. In order to increase the mirror surface quality, it is also possible to act in situ, using a thermal source, sent on the mirrors after a proper shaping. In this paper we present the results obtained on a tabletop Fabry-P\'erot Michelson interferometer illuminated with a ${\mathrm{LG}}_{3,3}$ mode. We show how an incoherent light source can reduce the astigmatism of one of the mirrors, increasing the quality of the beam in one of the Fabry-P\'erot cavities and then the contrast of the interferometer. The system has the potential to reduce more complex defects and also to be used in future gravitational-wave detectors using conventional Gaussian beams.