Magnetic Particle Imaging-Guided Heating <i>in Vivo</i> Using Gradient Fields for Arbitrary Localization of Magnetic Hyperthermia TherapyImage-guided treatment of cancer enables physicians to localize and treat tumors with great precision. Here, we present in vivo results showing that an emerging imaging modality, magnetic particle imaging (MPI), can be combined with magnetic hyperthermia into an image-guided theranostic platform. MPI is a noninvasive 3D tomographic imaging method with high sensitivity and contrast, zero ionizing radiation, and is linearly quantitative at any depth with no view limitations. The same superparamagnetic iron oxide nanoparticle (SPIONs) tracers imaged in MPI can also be excited to generate heat for magnetic hyperthermia. In this study, we demonstrate a theranostic platform, with quantitative MPI image guidance for treatment planning and use of the MPI gradients for spatial localization of magnetic hyperthermia to arbitrarily selected regions. This addresses a key challenge of conventional magnetic hyperthermia-SPIONs delivered systemically accumulate in off-target organs ( e.g., liver and spleen), and difficulty in localizing hyperthermia results in collateral heat damage to these organs. Using a MPI magnetic hyperthermia workflow, we demonstrate image-guided spatial localization of hyperthermia to the tumor while minimizing collateral damage to the nearby liver (1-2 cm distance). Localization of thermal damage and therapy was validated with luciferase activity and histological assessment. Apart from localizing thermal therapy, the technique presented here can also be extended to localize actuation of drug release and other biomechanical-based therapies. With high contrast and high sensitivity imaging combined with precise control and localization of the actuated therapy, MPI is a powerful platform for magnetic-based theranostics.
Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticlesContrast agents incorporating superparamagnetic iron-oxide nanoparticles have shown promise as a means to visualize labeled cells using MRI. Labeled cells cause significant signal dephasing due to the magnetic field inhomogeneity induced in water molecules near the cell. With the resulting signal void as the means for detection, the particles behave as a negative contrast agent, which can suffer from partial-volume effects. In this paper, a new method is described for imaging labeled cells with positive contrast. Spectrally selective RF pulses are used to excite and refocus the off-resonance water surrounding the labeled cells so that only the fluid and tissue immediately adjacent to the labeled cells are visible in the image. Phantom, in vitro, and in vivo experiments show the feasibility of the new method. A significant linear correlation (r = 0.87, P < 0.005) between the estimated number of cells and the signal was observed.
The X-Space Formulation of the Magnetic Particle Imaging Process: 1-D Signal, Resolution, Bandwidth, SNR, SAR, and MagnetostimulationPatrick Goodwill, Steven Conolly|IEEE Transactions on Medical Imaging|2010 The magnetic particle imaging (MPI) imaging process is a new method of medical imaging with great promise. In this paper we derive the 1-D MPI signal, resolution, bandwidth requirements, signal-to-noise ratio (SNR), specific absorption rate, and slew rate limitations. We conclude with experimental data measuring the point spread function for commercially available SPIO nanoparticles and a demonstration of the principles behind 1-D imaging using a static offset field. Despite arising from the nonlinear temporal response of a magnetic nanoparticle to a changing magnetic field, the imaging process is linear in the magnetization distribution and can be described as a convolution. Reconstruction in one dimension is exact and has a well-behaved quasi-Lorentzian point spread function.The spatial resolution improves cubically with increasing diameter of the SPIO domain, inverse to absolute temperature, linearly with saturation magnetization, and inversely with gradient. The band width requirements approach a megahertz for reasonable imaging parameters and millimeter scale resolutions, and the SNR increases with the scanning rate. The limit to SNR as we scale MPI to human sizes will be patient heating. SAR and magnetostimulation limits give us surprising relations between optimal scanning speeds and scanning frequency for different types of scanners.
Biogenic gas nanostructures as ultrasonic molecular reportersMagnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer DetectionCancer remains one of the leading causes of death worldwide. Biomedical imaging plays a crucial role in all phases of cancer management. Physicians often need to choose the ideal diagnostic imaging modality for each clinical presentation based on complex trade-offs among spatial resolution, sensitivity, contrast, access, cost, and safety. Magnetic particle imaging (MPI) is an emerging tracer imaging modality that detects superparamagnetic iron oxide (SPIO) nanoparticle tracer with high image contrast (zero tissue background signal), high sensitivity (200 nM Fe) with linear quantitation, and zero signal depth attenuation. MPI is also safe in that it uses safe, in some cases even clinically approved, tracers and no ionizing radiation. The superb contrast, sensitivity, safety, and ability to image anywhere in the body lends MPI great promise for cancer imaging. In this study, we show for the first time the use of MPI for in vivo cancer imaging with systemic tracer administration. Here, long circulating MPI-tailored SPIOs were created and administered intravenously in tumor bearing rats. The tumor was highlighted with tumor-to-background ratio of up to 50. The nanoparticle dynamics in the tumor was also well-appreciated, with initial wash-in on the tumor rim, peak uptake at 6 h, and eventual clearance beyond 48 h. Lastly, we demonstrate the quantitative nature of MPI through compartmental fitting in vivo.