I

Isabelle Fitton

Université Paris Cité

ORCID: 0000-0003-3360-9798

Publishes on Medical Imaging Techniques and Applications, Radiation Dose and Imaging, Advanced Radiotherapy Techniques. 52 papers and 945 citations.

52Publications
945Total Citations

Is this you? Claim your profile.

Add your photo, update your bio, and get notified when your ranking changes.

Top publicationsby citations

Decreased 3D observer variation with matched CT-MRI, for target delineation in Nasopharynx cancer
C. Rasch, Roel J.H.M. Steenbakkers, Isabelle Fitton et al.|Radiation Oncology|2010
Cited by 82Open Access

PURPOSE: To determine the variation in target delineation of nasopharyngeal carcinoma and the impact of measures to minimize this variation. MATERIALS AND METHODS: For ten nasopharyngeal cancer patients, ten observers each delineated the Clinical Target Volume (CTV) and the CTV elective. After 3D analysis of the delineated volumes, a second delineation was performed. This implied improved delineation instructions, a combined delineation on CT and co-registered MRI, forced use of sagittal reconstructions, and an on-line anatomical atlas. RESULTS: Both for the CTV and the CTV elective delineations, the 3D SD decreased from Phase 1 to Phase 2, from 4.4 to 3.3 mm for the CTV and from 5.9 to 4.9 mm for the elective. There was an increase agreement, where the observers intended to delineate the same structure, from 36 to 64 surface % (p = 0.003) for the CTV and from 17 to 59% (p = 0.004) for the elective. The largest variations were at the caudal border of the delineations but these were smaller when an observer utilized the sagittal window. Hence, the use of sagittal side windows was enforced in the second phase and resulted in a decreased standard deviation for this area from 7.7 to 3.3 mm (p = 0.001) for the CTV and 7.9 to 5.6 mm (p = 0.03) for the CTV elective. DISCUSSION: Attempts to decrease the variation need to be tailored to the specific causes of the variation. Use of delineation instructions multimodality imaging, the use of sagittal windows and an on-line atlas result in a higher agreement on the intended target.

Efficacy of Chest CT for COVID-19 Pneumonia Diagnosis in France
Cited by 81Open Access

Background The role and performance of chest CT in the diagnosis of the coronavirus disease 2019 (COVID-19) pandemic remains under active investigation. Purpose To evaluate the French national experience using chest CT for COVID-19, results of chest CT and reverse transcription polymerase chain reaction (RT-PCR) assays were compared together and with the final discharge diagnosis used as the reference standard. Materials and Methods A structured CT scan survey (NCT04339686) was sent to 26 hospital radiology departments in France between March 2, 2020, and April 24, 2020. These dates correspond to the peak of the national COVID-19 epidemic. Radiology departments were selected to reflect the estimated geographic prevalence heterogeneities of the epidemic. All symptomatic patients suspected of having COVID-19 pneumonia who underwent both initial chest CT and at least one RT-PCR test within 48 hours were included. The final discharge diagnosis, based on multiparametric items, was recorded. Data for each center were prospectively collected and gathered each week. Test efficacy was determined by using the Mann-Whitney test, Student t test, χ2 test, and Pearson correlation coefficient. P < .05 indicated a significant difference. Results Twenty-six of 26 hospital radiology departments responded to the survey, with 7500 patients entered; 2652 did not have RT-PCR test results or had unknown or excess delay between the RT-PCR test and CT. After exclusions, 4824 patients (mean age, 64 years ± 19 [standard deviation], 2669 male) were included. With final diagnosis as the reference, 2564 of the 4824 patients had COVID-19 (53%). Sensitivity, specificity, negative predictive value, and positive predictive value of chest CT in the diagnosis of COVID-19 were 2319 of 2564 (90%; 95% CI: 89, 91), 2056 of 2260 (91%; 95% CI: 91, 92), 2056 of 2300 (89%; 95% CI: 87, 90), and 2319 of 2524 (92%; 95% CI: 91, 93), respectively. There was no significant difference for chest CT efficacy among the 26 geographically separate sites, each with varying amounts of disease prevalence. Conclusion Use of chest CT for the initial diagnosis and triage of patients suspected of having coronavirus disease 2019 was successful. © RSNA, 2021 Online supplemental material is available for this article.