Sensitivity of Blood Volume Monitoring for Fluid Status Assessment in Hemodialysis PatientsBACKGROUND/AIMS: This study investigates the use of blood volume monitoring (BVM) markers for the assessment of fluid status. METHODS: Predialysis fluid overload (FO) and BVM data were collected in 55 chronic hemodialysis patients in 317 treatments. Predialysis FO was measured using bioimpedance spectroscopy. The slope of the intravascular volume decrease over time normalized by ultrafiltration rate (Slope4h) was used as the primary BVM marker and compared against FO. RESULTS: Average relative blood volume curves were well separated in different FO groups between 0 and 5 liters. Receiver-operating characteristics analysis revealed that the sensitivity of BVM was moderate in median FO ranges between 1 and 3 liters (AUC 0.60-0.65), slightly higher for volume depletion of FO <1 liter (AUC 0.7) and highest for excess fluid of FO >3 liters (AUC 0.85). CONCLUSION: Devices that monitor blood volume are well suited to detect high FO, but are not as sensitive at moderate or low levels of fluid status.
Bioimpedance-Guided Fluid Management in Hemodialysis PatientsUlrich Moissl, Marta Arias‐Guillén, Peter Wabel et al.|Clinical Journal of the American Society of Nephrology|2013 BACKGROUND AND OBJECTIVES: Achieving and maintaining optimal fluid status remains a major challenge in hemodialysis therapy. The aim of this interventional study was to assess the feasibility and clinical consequences of active fluid management guided by bioimpedance spectroscopy in chronic hemodialysis patients. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Fluid status was optimized prospectively in 55 chronic hemodialysis patients over 3 months (November 2011 to February 2012). Predialysis fluid overload was measured weekly using the Fresenius Body Composition Monitor. Time-averaged fluid overload was calculated as the average between pre- and postdialysis fluid overload. The study aimed to bring the time-averaged fluid overload of all patients into a target range of 0.5 ± 0.75 L within the first month and maintain optimal fluid status until study end. Postweight was adjusted weekly according to a predefined protocol. RESULTS: Time-averaged fluid overload in the complete study cohort was 0.9 ± 1.6 L at baseline and 0.6 ± 1.1 L at study end. Time-averaged fluid overload decreased by -1.20 ± 1.32 L (P<0.01) in the fluid-overloaded group (n=17), remained unchanged in the normovolemic group (n=26, P=0.59), and increased by 0.59 ± 0.76 L (P=0.02) in the dehydrated group (n=12). Every 1 L change in fluid overload was accompanied by a 9.9 mmHg/L change in predialysis systolic BP (r=0.55, P<0.001). At study end, 76% of all patients were either on time-averaged fluid overload target or at least closer to target than at study start. The number of intradialytic symptoms did not change significantly in any of the subgroups. CONCLUSIONS: Active fluid management guided by bioimpedance spectroscopy was associated with an improvement in overall fluid status and BP.
SHARPS INJURIES AMONGST HEALTHCARE WORKERS: REVIEW OF INCIDENCE, TRANSMISSIONS AND COSTSBACKGROUND: Sharps injuries and the related risk of infections such as hepatitis B virus (HBV), hepatitis C virus (HCV) and human immunodeficiency virus (HIV) represent one of the major occupational health risks for healthcare workers (HCWs). LITERATURE REVIEW: An overview of available data on the incidence of sharps injuries and the related HBV, HCV and HIV infections and ensuing costs is provided. RESULTS: Literature reported incidence rates of sharps injuries ranging from 1.4 to 9.5 per 100 HCWs, resulting in a weighted mean of 3.7/100 HCWs per year. Sharps injuries were associated with infective disease transmissions from patients to HCWs resulting in 0.42 HBV infections, 0.05-1.30 HCV infections and 0.04-0.32 HIV infections per 100 sharps injuries per year. The related societal costs had a mean of €272, amounting to a mean of €1,966 if the source patient was HIV positive with HBV and HCV co-infections. CONCLUSION: Sharps injuries remain a frequent threat amongst HCWs. The follow-up and treatment of sharps injuries and the deriving consequences represent a significant cost factor.
Medium Cut-Off Dialyzer versus Eight Hemodiafiltration Dialyzers: Comparison Using a Global Removal ScoreBACKGROUND: A novel class of membranes, medium cut-off (MCO) membranes, has recently been designed to achieve interesting removal capacities for middle and large middle molecules in hemodialysis (HD) treatments. The few studies published to date have reported contradictory results regarding middle-sized molecules when comparing MCO dialyzers versus dialyzers used in online hemodiafiltration (OL-HDF). METHODS: A prospective, single-center study was carried out in 22 patients. Each patient underwent 9 dialysis sessions with routine dialysis parameters, one with an MCO dialyzer in HD and the other 8 with different dialyzers in OL-HDF. The removal ratio (RR) of urea, creatinine, β2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, and albumin was intraindividually compared. Albumin loss in dialysate was measured. We propose a global removal score ([ureaRR + β2-microglobulinRR + myoglobinRR + prolactinRR + α1-microglobulinRR + α1-acid glycoproteinRR]/6 - albuminRR) as a new tool for measuring dialyzer effectiveness. RESULTS: No significant differences in the RRs of small and middle molecular range molecules were observed between the MCO vs. OL-HDF dialyzers (range 60-80%). Lower RRs were found for α1-microglobulin and α1-acid glycoprotein without significant differences. The albumin RR was < 11% and dialysate albumin loss was < 3.5 g in all situations without significant differences. The global removal score was 54.9 ± 4.8% with the MCO dialyzer without significant differences. CONCLUSIONS: Removal of a wide range of molecular weights, calculated with the proposed global removal score, was almost equal with the MCO dialyzer in HD treatment compared with 8 high-flux dialyzers in high-volume OL-HDF without relevant changes in albumin loss. The global removal score could be a new tool to evaluate the effectiveness of dialyzers and/or different treatment modalities.
Elimination of Large Uremic Toxins by a Dialyzer Specifically Designed for High-Volume Convective TherapiesBACKGROUND: Unlike conventional hemodialysis treatments, which rely almost solely on diffusion-related mechanisms for solute removal, hemodiafiltration (HDF) allows more efficient removal of higher molecular weight toxins due to convective transport mechanisms. To facilitate the removal of these toxins in HDF treatment modalities, dialyzers with highly efficient high-flux membranes are necessary. This study assessed the large uremic toxin removal ability of a high-flux dialyzer (FX CorDiax 60) specifically designed to facilitate convective therapies compared with a standard high-flux dialyzer (FX 60). METHODS: In an open, randomized, cross-over, single-center, controlled, prospective clinical study, 30 adult chronic hemodialysis patients were treated by post-dilution online HDF with the FX 60 or the FX CorDiax 60 dialyzer. All other dialysis parameters were kept constant in both study arms. The reduction rate (RR) of blood urea nitrogen, phosphate, β2-microglobulin (β2-m), myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, albumin and total protein as well as the elimination into dialysate was intraindividually compared for the two dialyzer types. RESULTS: For FX CorDiax 60 versus FX 60, the RR was significantly higher for blood urea nitrogen (86.23 ± 4.14 vs. 84.89 ± 4.59%, p = 0.015), β2-m (84.67 ± 3.79 vs. 81.30 ± 4.82%, p < 0.0001), myoglobin (75.23 ± 10.48 vs. 58.60 ± 12.1%, p < 0.0001), prolactin (72.96 ± 9.68 vs. 56.91 ± 13.01%, p < 0.0001) and α1-microglobulin (20.89 ± 18.27 vs. 13.60 ± 12.50%, p = 0.016). There were no significant differences in the RR for phosphate, α1-acid glycoprotein, albumin and total protein. Mass removal was significantly higher with the FX CorDiax 60 than with the FX 60 for β2-m (0.26 ± 0.09 vs. 0.24 ± 0.09 g, p = 0.0006), myoglobin (1.83 ± 0.89 vs. 1.51 ± 0.76 mg, p = 0.0017), prolactin (0.17 ± 0.13 vs. 0.14 ± 0.08 mg, p = 0.02) and albumin (4.25 ± 3.49 vs. 3.01 ± 2.37 g, p = 0.03). CONCLUSIONS: This study demonstrates that treating patients with an FX CorDiax 60 instead of an FX 60 dialyzer in post-dilution HDF mode significantly increases the elimination of middle molecules.