A

Amy C. Rowat

California NanoSystems Institute

ORCID: 0000-0001-5800-5320

Publishes on Cellular Mechanics and Interactions, 3D Printing in Biomedical Research, Nuclear Structure and Function. 149 papers and 8.3k citations.

149Publications
8.3kTotal Citations

Is this you? Claim your profile.

Add your photo, update your bio, and get notified when your ranking changes.

Top publicationsby citations

Ultrahigh-throughput screening in drop-based microfluidics for directed evolution
Jeremy J. Agresti, Eugene Antipov, Adam R. Abate et al.|Proceedings of the National Academy of Sciences|2010
Cited by 1.1kOpen Access

The explosive growth in our knowledge of genomes, proteomes, and metabolomes is driving ever-increasing fundamental understanding of the biochemistry of life, enabling qualitatively new studies of complex biological systems and their evolution. This knowledge also drives modern biotechnologies, such as molecular engineering and synthetic biology, which have enormous potential to address urgent problems, including developing potent new drugs and providing environmentally friendly energy. Many of these studies, however, are ultimately limited by their need for even-higher-throughput measurements of biochemical reactions. We present a general ultrahigh-throughput screening platform using drop-based microfluidics that overcomes these limitations and revolutionizes both the scale and speed of screening. We use aqueous drops dispersed in oil as picoliter-volume reaction vessels and screen them at rates of thousands per second. To demonstrate its power, we apply the system to directed evolution, identifying new mutants of the enzyme horseradish peroxidase exhibiting catalytic rates more than 10 times faster than their parent, which is already a very efficient enzyme. We exploit the ultrahigh throughput to use an initial purifying selection that removes inactive mutants; we identify approximately 100 variants comparable in activity to the parent from an initial population of approximately 10(7). After a second generation of mutagenesis and high-stringency screening, we identify several significantly improved mutants, some approaching diffusion-limited efficiency. In total, we screen approximately 10(8) individual enzyme reactions in only 10 h, using < 150 microL of total reagent volume; compared to state-of-the-art robotic screening systems, we perform the entire assay with a 1,000-fold increase in speed and a 1-million-fold reduction in cost.

Designer emulsions using microfluidics
Rhutesh K. Shah, Ho Cheung Shum, Amy C. Rowat et al.|Materials Today|2008
Cited by 754Open Access

We describe new developments for the controlled fabrication of monodisperse emulsions using microfluidics. We use glass capillary devices to generate single, double, and higher order emulsions with exceptional precision. These emulsions can serve as ideal templates for generating well-defined particles and functional vesicles. Polydimethylsiloxane microfluidic devices are also used to generate picoliter-scale water-in-oil emulsions at rates as high as 10 000 drops per second. These emulsions have great potential as individual microvessels in high-throughput screening applications, where each drop serves to encapsulate single cells, genes, or reactants.

Biocompatible surfactants for water-in-fluorocarbon emulsions
Christian Holtze, Amy C. Rowat, Jeremy J. Agresti et al.|Lab on a Chip|2008
Cited by 660Open Access

Drops of water-in-fluorocarbon emulsions have great potential for compartmentalizing both in vitro and in vivo biological systems; however, surfactants to stabilize such emulsions are scarce. Here we present a novel class of fluorosurfactants that we synthesize by coupling oligomeric perfluorinated polyethers (PFPE) with polyethyleneglycol (PEG). We demonstrate that these block copolymer surfactants stabilize water-in-fluorocarbon oil emulsions during all necessary steps of a drop-based experiment including drop formation, incubation, and reinjection into a second microfluidic device. Furthermore, we show that aqueous drops stabilized with these surfactants can be used for in vitro translation (IVT), as well as encapsulation and incubation of single cells. The compatability of this emulsion system with both biological systems and polydimethylsiloxane (PDMS) microfluidic devices makes these surfactants ideal for a broad range of high-throughput, drop-based applications.

Drop-based microfluidic devices for encapsulation of single cells
Sarah Köster, Francesco E. Angilè, Honey Duan et al.|Lab on a Chip|2008
Cited by 520Open Access

We use microfluidic devices to encapsulate, incubate, and manipulate individual cells in picoliter aqueous drops in a carrier fluid at rates of up to several hundred Hz. We use a modular approach with individual devices for each function, thereby significantly increasing the robustness of our system and making it highly flexible and adaptable to a variety of cell-based assays. The small volumes of the drops enables the concentrations of secreted molecules to rapidly attain detectable levels. We show that single hybridoma cells in 33 pL drops secrete detectable concentrations of antibodies in only 6 h and remain fully viable. These devices hold the promise of developing microfluidic cell cytometers and cell sorters with much greater functionality, allowing assays to be performed on individual cells in their own microenvironment prior to analysis and sorting.