Current Estimates of Cochlear Implant Utilization in the United StatesOBJECTIVE: To present key data from a private marketing report that characterizes U.S. cochlear implant (CI) utilization, potential CI candidate and recipient population sizes, and CI market growth. PATIENTS: Individuals who may benefit from CI and CI recipients in the United States. INTERVENTIONS: Cochlear implantation. MAIN OUTCOME MEASURES: CI utilization, potential CI candidate and recipient population sizes, and CI market size and value. RESULTS: As of 2015, a cumulative 170,252 people (240,056 devices) had undergone cochlear implantation in the United States. In the year 2015, approximately 30% of devices were implanted in bilateral CI patients, through simultaneous or sequential implantation. When considering traditional audiometric CI candidacy criteria (patients with severe to profound sensorineural hearing loss in the better hearing ear), utilization rates among the population who may benefit from CI approximated 12.7%. When considering expanded criteria including individuals with single-sided deafness or asymmetrical hearing loss (severe to profound hearing loss in the worse hearing ear), utilization rates approximated 2.1%. In 2015, there was a net increase of 20,093 individuals who may have benefited from CI who had not undergone CI, adding to the group of about 1.3 M untreated audiometric CI candidates who existed prior to that year. The CI market was valued at $450.8 M in 2015, with an average device selling price of $25,701 per device. CONCLUSIONS: CI utilization rates remain low among individuals who meet audiometric criteria for CI. Although the annual proportion of CI recipients to new audiometric candidates has increased, the total population of untreated audiometric CI candidates continues to rise.
Barriers to Adult Cochlear Implant Care in the United States: An Analysis of Health Care DeliveryPersistent underutilization of cochlear implants (CIs) in the United States is in part a reflection of a lack of hearing health knowledge and the complexities of care delivery in the treatment of sensorineural hearing loss. An evaluation of the patient experience through the CI health care delivery process systematically exposes barriers that must be overcome to undergo treatment for moderate-to-severe hearing loss. This review analyzes patient-facing obstacles including diagnosis of hearing loss, CI candidate identification and referral to surgeon, CI evaluation and candidacy criteria interpretation, and lastly CI surgery and rehabilitation. Pervasive throughout the process are several themes which demand attention in addressing inequities in hearing health disparities in the United States.
Prospective Study of Disease-Specific Quality-of-Life in Sporadic Vestibular Schwannoma Comparing Observation, Radiosurgery, and MicrosurgeryBACKGROUND: Previous cross-sectional studies analyzing quality of life (QOL) outcomes in patients with sporadic vestibular schwannoma (VS) have shown surprisingly little difference among treatment modalities. To date, there is limited prospective QOL outcome data available comparing baseline to posttreatment scores. STUDY DESIGN: Prospective longitudinal study using the disease-specific Penn Acoustic Neuroma Quality of Life (PANQOL) scale. SETTING: Large academic skull base center. PATIENTS: Patients diagnosed with unilateral VS who completed a baseline survey before treatment and at least one posttreatment survey. MAIN OUTCOME MEASURES: Change in PANQOL scores from baseline to most recent survey. RESULTS: A total of 244 patients were studied, including 78 (32%) who elected observation, 118 (48%) microsurgery, and 48 (20%) stereotactic radiosurgery. Patients who underwent microsurgery were younger (p < 0.001) and had larger tumors (p < 0.001) than those who underwent observation or radiosurgery; there was no significant difference in duration of follow-up among management groups (mean 2.1 yrs; p = 0.28). When comparing the total PANQOL score at baseline to the most recent survey, the net change was only -1.1, -0.1, and 0.3 points on a 100-point scale for observation, microsurgery, and radiosurgery, respectively (p = 0.89). After multivariable adjustment for baseline features, there were no statistically significant changes when comparing baseline to most recent scores within each management group for facial function, general health, balance, hearing loss, energy, and pain domains or total score. However, the microsurgical group experienced a 10.8-point improvement (p = 0.002) in anxiety following treatment, compared with 1.5 (p = 0.73) and 5.3 (p = 0.31) for observation and radiosurgery, respectively. CONCLUSIONS: In this prospective longitudinal study investigating differences in QOL outcomes among VS treatment groups using the disease-specific PANQOL instrument, treatment did not modify QOL in most domains. Microsurgery may confer an advantage with regard to patient anxiety, presumably relating to the psychological benefit of "cure" from having the tumor removed.
Long-term natural history and patterns of sporadic vestibular schwannoma growth: A multi-institutional volumetric analysis of 952 patientsBACKGROUND: The current study aims to characterize the natural history of sporadic vestibular schwannoma volumetric tumor growth, including long-term growth patterns following initial detection of growth. METHODS: Volumetric tumor measurements from 3505 serial MRI studies were analyzed from unselected consecutive patients undergoing wait-and-scan management at three tertiary referral centers between 1998 and 2018. Volumetric tumor growth was defined as a change in volume ≥20%. RESULTS: Among 952 patients undergoing observation, 622 experienced tumor growth with initial growth-free survival rates (95% CI) at 1, 3, and 5 years following diagnosis of 66% (63-69), 30% (27-34), and 20% (17-24). Among 405 patients who continued to be observed despite demonstrating initial growth, 210 experienced subsequent tumor growth with subsequent growth-free survival rates at 1, 3, and 5 years following initial growth of 77% (72-81), 37% (31-43), and 24% (18-31). Larger tumor volume at initial growth (HR 1.13, P = .02) and increasing tumor growth rate (HR 1.31; P < .001) were significantly associated with an increased likelihood of subsequent growth, whereas a longer duration of time between diagnosis and detection of initial growth was protective (HR 0.69; P < .001). CONCLUSIONS: While most vestibular schwannomas exhibit an overall propensity for volumetric growth following diagnosis, prior tumor growth does not perfectly predict future growth. Tumors can subsequently grow faster, slower, or demonstrate quiescence and stability. Larger tumor size and increasing tumor growth rate portend a higher likelihood of continued growth. These findings can inform timing of intervention: whether upfront at initial diagnosis, after detection of initial growth, or only after continued growth is observed.
Matched Cohort Comparison Indicates Superiority of Precurved Electrode ArraysOBJECTIVE: Characterize differences in adult cochlear implant outcomes and programming parameters for a straight (CI422/522) and a precurved (CI532) electrode array. SETTING: Cochlear implant (CI) program at a tertiary otologic center. PATIENTS: Fifty-eight adults were included in the study; 29 were implanted with CI422 or CI522 and 29 were implanted with CI532. Each CI532 recipient was matched to a CI422/522 recipient in terms of age and preoperative hearing thresholds for comparison purposes. MAIN OUTCOME MEASURES: Consonant-Nucleus-Consonant (CNC) words, AzBio sentences, residual audiometric thresholds, and Speech Spatial Qualities (SSQ) questionnaire collected 6 months postoperatively were used to characterize outcomes. Pulse duration, maxima, impedances, and overall charge measurements were used to characterize programming parameters. RESULTS: Postoperative unaided low frequency pure-tone average (LFPTA) was significantly better for the CI532 group. CNC scores were significantly better for the CI532 group. Impedances and pulse duration were significantly lower for the CI532 group, but there was no difference in overall charge between the groups. CONCLUSION: The CI532 group showed either similar or statistically superior results on all measures when compared with the CI422/522 suggesting that the CI532 electrode may be an advantageous substitute for the CI522.