Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of ProteinsAn ultrasensitive method for detecting protein analytes has been developed. The system relies on magnetic microparticle probes with antibodies that specifically bind a target of interest [prostate-specific antigen (PSA) in this case] and nanoparticle probes that are encoded with DNA that is unique to the protein target of interest and antibodies that can sandwich the target captured by the microparticle probes. Magnetic separation of the complexed probes and target followed by dehybridization of the oligonucleotides on the nanoparticle probe surface allows the determination of the presence of the target protein by identifying the oligonucleotide sequence released from the nanoparticle probe. Because the nanoparticle probe carries with it a large number of oligonucleotides per protein binding event, there is substantial amplification and PSA can be detected at 30 attomolar concentration. Alternatively, a polymerase chain reaction on the oligonucleotide bar codes can boost the sensitivity to 3 attomolar. Comparable clinically accepted conventional assays for detecting the same target have sensitivity limits of approximately 3 picomdar, six orders of magnitude less sensitive than what is observed with this method.
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*An ultrasensitive method for detecting protein analytes has been developed. The system relies on magnetic microparticle probes with antibodies that specifically bind a target of interest [prostate-specific antigen (PSA) in this case] and nanoparticle probes that are encoded with DNA that is unique to the protein target of interest and antibodies that can sandwich the target captured by the microparticle probes. 1480Magnetic separation of the complexed probes and target followed by dehybridization of the oligonucleotides on the nanoparticle probe surface allows the determination of the presence of the target protein by identifying the oligonucleotide sequence released from the nanoparticle probe. Because the nanoparticle probe carries with it a large number of oligonucleotides per protein binding event, there is substantial amplification, and PSA can be detected at 30 attomolar concentration. Alternatively, a polymerase chain reaction on the oligonucleotide barcodes can boost the sensitivity to 3 attomolar. Comparable clinically accepted conventional assays for detecting the same target have sensitivity limits of ~3 picomolar, 6 orders of magnitude less sensitive than what is observed with this method.
Oligonucleotide-Modified Gold Nanoparticles for Intracellular Gene RegulationWe describe the use of gold nanoparticle-oligonucleotide complexes as intracellular gene regulation agents for the control of protein expression in cells. These oligonucleotide-modified nanoparticles have affinity constants for complementary nucleic acids that are higher than their unmodified oligonucleotide counterparts, are less susceptible to degradation by nuclease activity, exhibit greater than 99% cellular uptake, can introduce oligonucleotides at a higher effective concentration than conventional transfection agents, and are nontoxic to the cells under the conditions studied. By chemically tailoring the density of DNA bound to the surface of gold nanoparticles, we demonstrated a tunable gene knockdown.
Nanoparticle-based detection in cerebral spinal fluid of a soluble pathogenic biomarker for Alzheimer's diseaseD.G. Georganopoulou, Lei Chang, Jwa‐Min Nam et al.|Proceedings of the National Academy of Sciences|2005 The recently developed ultrasensitive bio-barcode assay was used to measure the concentration of amyloid-beta-derived diffusible ligands (ADDLs), a potential soluble pathogenic Alzheimer's disease (AD) marker, in the cerebrospinal fluid (CSF) of 30 individuals. ADDL concentrations for the subjects diagnosed with AD were consistently higher than the levels in the CSF taken from nondemented age-matched controls. Studies of ADDLs or for any other potential pathogenic AD markers in CSF have not been possible because of their low concentration in CSF (<1 pM). This study is a step toward a diagnostic tool, based on soluble pathogenic markers for the debilitating disease.
Nanoparticle-based bio-barcode assay redefines “undetectable” PSA and biochemical recurrence after radical prostatectomyC. Shad Thaxton, Robert Elghanian, Audrey Thomas et al.|Proceedings of the National Academy of Sciences|2009 We report the development of a previously undescribed gold nanoparticle bio-barcode assay probe for the detection of prostate specific antigen (PSA) at 330 fg/mL, automation of the assay, and the results of a clinical pilot study designed to assess the ability of the assay to detect PSA in the serum of 18 men who have undergone radical prostatectomy for prostate cancer. Due to a lack of sensitivity, available PSA immunoassays are often not capable of detecting PSA in the serum of men after radical prostatectomy. This new bio-barcode PSA assay is approximately 300 times more sensitive than commercial immunoassays. Significantly, with the barcode assay, every patient in this cohort had a measurable serum PSA level after radical prostatectomy. Patients were separated into categories based on PSA levels as a function of time. One group of patients showed low levels of PSA with no significant increase with time and did not recur. Others showed, at some point postprostatectomy, rising PSA levels. The majority recurred. Therefore, this new ultrasensitive assay points to significant possible outcomes: (i) The ability to tell patients, who have undetectable PSA levels with conventional assays, but detectable and nonrising levels with the barcode assay, that their cancer will not recur. (ii) The ability to assign recurrence earlier because of the ability to measure increasing levels of PSA before conventional tools can make such assignments. (iii) The ability to use PSA levels that are not detectable with conventional assays to follow the response of patients to adjuvant or salvage therapies.