A Prospective, Multicenter, Randomized Trial of Paclitaxel-Coated Balloon Versus Paclitaxel-Eluting Stent for the Treatment of Drug-Eluting Stent In-Stent Restenosis

Bo Xu(Fu Wai Hospital), Runlin Gao(Fu Wai Hospital), Jianan Wang(Second Affiliated Hospital of Zhejiang University), Yuejin Yang(Fu Wai Hospital), Shao‐Liang Chen(Nanjing Medical University), Bin Liu(Second Affiliated Hospital of Jilin University), Fang Chen(Capital Medical University), Zhanquan Li(Liaoning Provincial People's Hospital), Yaling Han(General Hospital of Shenyang Military Region), Guosheng Fu(Sir Run Run Shaw Hospital), Yelin Zhao(Fu Wai Hospital), Junbo Ge(Fudan University)
JACC: Cardiovascular Interventions
February 1, 2014
Cited by 173Open Access
Full Text

Abstract

OBJECTIVES: The intention of the PEPCAD China ISR (A Prospective, Multicenter, Randomized Trial of Paclitaxel-Coated versus Paclitaxel-Eluting Stent for the Treatment of Drug-Eluting Stent In-Stent Restenosis) was to demonstrate the efficacy of paclitaxel-coated balloon (PCB) angioplasty in a non-European patient population with coronary drug-eluting stent in-stent restenosis (DES-ISR). BACKGROUND: The treatment of DES-ISR is still challenging with no established best strategy. Moreover, there is no study on the effect of PCB in the treatment of ISR in the Chinese population. METHODS: PEPCAD China ISR was a 220-patient randomized (1:1), single-blind prospective multicenter trial conducted in China. Patients with coronary DES-ISR received either PCB (SeQuent Please, B. Braun Melsungen AG, Melsungen, Germany) or paclitaxel-eluting stent (Taxus Liberté, Boston Scientific, Natick, Massachusetts) treatment. The primary endpoint was in-segment late lumen loss at 9 months. RESULTS: There were no significant baseline differences between both treatment groups in terms of patient, lesion, or procedural characteristics. At 9 months, in-segment late lumen loss in the PCB group was noninferior to that of the paclitaxel-eluting stent group (0.46 ± 0.51 mm vs. 0.55 ± 0.61 mm; difference: -0.06 mm with 95% confidence interval: -0.23 to 0.10; p for noninferiority = 0.0005). The 9-month rate of binary restenosis and 12-month composite clinical event rates were not significantly different between groups. CONCLUSIONS: In a randomized trial of 220 patients, angioplasty with a PCB was noninferior to paclitaxel-eluting stent implantation when used to treat DES-ISR. On the basis of these, as well as previous randomized trial data, PCB angioplasty offers an effective treatment for DES-ISR without the necessity of implanting additional metal layers for drug release. (A Safety and Efficacy Study of Paclitaxel-Eluting Balloon to Paclitaxel-Eluting Stent [PEPCAD]; NCT01622075).


Related Papers

No related papers found

Powered by citation graph analysis