Sissel Kronborg-White(Aarhus University Hospital), Elisabeth Bendstrup(Aarhus University Hospital), Leonardo Gori(Society of Interventional Radiology), Valentina Luzzi(Society of Interventional Radiology), Line Bille Madsen(Aarhus University Hospital), Venerino Poletti(Aarhus University Hospital), Torben Riis Rasmussen(Aarhus University Hospital), Marco Trigiani(Society of Interventional Radiology), Stefano Vezzosi(Azienda Ospedaliero-Universitaria Careggi), Sara Tomassetti(Society of Interventional Radiology)
Pulmonology
September 12, 2021
Cited by 24Open Access
Full Text

Abstract

BACKGROUND: Transbronchial cryobiopsies has become increasingly important in the diagnostic workup for interstitial lung diseases. The rate of complications and mortality are low compared to surgical lung biopsies, but the diagnostic yield is not as high. The reason for the lower diagnostic yield could in some cases be explained by biopsies taken too centrally or in less affected areas. In this pilot study we examined the feasibility of using the electromagnetic navigation system, superDimension (SD), when performing cryobiopsies to increase the diagnostic yield. METHODS: Electromagnetic navigation bronchoscopy and cryobiopsies were performed using SD. An electromagnetic board placed on the back of the patient and a position sensor at the tip of the navigational probe created a real-time 3D reconstruction of previously acquired computer tomography images. The procedure was performed with the patients in general anesthesia using a rigid bronchoscope when performed in Florence and with a flexible bronchoscope through an orotracheal tube when performed in Aarhus. RESULTS: In total, 18 patients were included. Five patients were excluded, partly due to technical difficulties. Disposable 1.7 mm cryoprobes were used in Aarhus, and reusable 1.9 mm probes in Florence. Pneumothorax was detected in three (23%), mild hemorrhage was seen in one (8%) and moderate hemorrhage in six (46%). The biopsies contributed to the diagnosis in 11 of the patients (85%). CONCLUSION: Using superDimension electromagnetic navigation system when performing cryobiopsies is feasible. A larger prospective trial is necessary to homogenize the technique between centres and to evaluate diagnostic advantage and complications.


Related Papers

No related papers found

Powered by citation graph analysis