Abstract
= 196) in Lausanne (Switzerland). Clinical data were used to investigate discrepant results. Correlation between semiquantitative result of Ultra and smear microscopy status for the detection of acid-fast bacilli (AFB) was established. The sensitivities of Xpert and Ultra were 82.9% (39/47) and 95.8% (45/47), respectively, when considering all culture-positive specimens, 100% (23/23) for both assays on smear-positive specimens, and 66.7% (16/24) and 91.7% (22/24) on smear-negative specimens. Using culture as gold standard, the specificities of Xpert and Ultra were 97.3% (145/149) and 96.64% (144/149), respectively. All the patients with Ultra-positive results with the new category "trace" were diagnosed with active TB based on clinical findings and microbiological culture. The semiquantitative results of both Xpert and of Ultra positively correlated with the semiquantitative result of AFB detection. Our data support an increased sensitivity of Ultra compared to Xpert in a low-prevalence setting. Correlation between the Ultra semiquantitative result and AFB burden can help in evaluating a patient's transmission potential.