Diagnosis of small pulmonary lesions by transbronchial lung biopsy with radial endobronchial ultrasound and virtual bronchoscopic navigation versus CT-guided transthoracic needle biopsy: A systematic review and meta-analysis

Yeji Han(Ewha Womans University), Hyun Jung Kim(Korea University), Kyoung Ae Kong(Ewha Womans University), Soo Jung Kim(Ewha Womans University), Su Hwan Lee(Ewha Womans University), Yon Ju Ryu(Ewha Womans University), Jin Hwa Lee(Ewha Womans University), Yookyoung Kim(Ewha Womans University), Sung Shine Shim(Ewha Womans University), Jung Hyun Chang(Ewha Womans University)
PLoS ONE
January 22, 2018
Cited by 137Open Access
Full Text

Abstract

BACKGROUND: Advances in bronchoscopy and CT-guided lung biopsy have improved the evaluation of small pulmonary lesions (PLs), leading to an increase in preoperative histological diagnosis. We aimed to evaluate the efficacy and safety of transbronchial lung biopsy using radial endobronchial ultrasound and virtual bronchoscopic navigation (TBLB-rEBUS&VBN) and CT-guided transthoracic needle biopsy (CT-TNB) for tissue diagnosis of small PLs. METHODS: A systematic search was performed in five electronic databases, including MEDLINE, EMBASE, Cochrane Library Central Register of Controlled Trials, Web of Science, and Scopus, for relevant studies in May 2016; the selected articles were assessed using meta-analysis. The articles were limited to those published after 2000 that studied small PLs ≤ 3 cm in diameter. RESULTS: From 7345 records, 9 articles on the bronchoscopic (BR) approach and 15 articles on the percutaneous (PC) approach were selected. The pooled diagnostic yield was 75% (95% confidence interval [CI], 69-80) using the BR approach and 93% (95% CI, 90-96) using the PC approach. For PLs ≤ 2 cm, the PC approach (pooled diagnostic yield: 92%, 95% CI: 88-95) was superior to the BR approach (66%, 95% CI: 55-76). However, for PLs > 2 cm but ≤ 3 cm, the diagnostic yield using the BR approach was improved to 81% (95% CI, 75-85). Complications of pneumothorax and hemorrhage were rare with the BR approach but common with the PC approach. CONCLUSIONS: CT-TNB was superior to TBLB-rEBUS&VBN for the evaluation of small PLs. However, for lesions greater than 2 cm, the BR approach may be considered considering its diagnostic yield of over 80% and the low risk of procedure-related complications.


Related Papers

No related papers found

Powered by citation graph analysis