Optimizing Radiolabeled Engineered Anti-p185HER2 Antibody Fragments for <i>In vivo</i> Imaging

Tove Olafsen(University of California, Los Angeles), Vania Kenanova(University of California, Los Angeles), Gobalakrishnan Sundaresan(University of California, Los Angeles), Anne-Line Anderson, Desiree Crow, Paul J. Yazaki, Lin Li(City of Hope), Michael F. Press(University of Southern California), Sanjiv S. Gambhir(Stanford University), Lawrence E. Williams, Jeffrey Y.C. Wong(City Of Hope National Medical Center), Andrew Raubitschek, John E. Shively(City of Hope), Anna M. Wu(University of California, Los Angeles)
Cancer Research
July 1, 2005
Cited by 154Open Access
Full Text

Abstract

We have recently described the in vivo properties of an iodinated anti-p185HER2 engineered antibody fragment [minibody (scFv-C(H)3)2; 80 kDa], made from the internalizing 10H8 monoclonal antibody. Although the 10H8 minibody showed excellent binding to the target in vitro, only modest tumor uptake [5.6 +/- 1.7% injected dose per gram (ID/g) of tissue] was achieved in nude mice bearing MCF7/HER2 breast cancer tumors. Here, in an attempt to improve targeting, the 10H8 minibody was conjugated to 1,4,7,10-tetraazacyclododecane-N, N', N'', N'''-tetraacetic acid (DOTA), radiometal labeled, and evaluated in vivo. The tumor uptake of 111In-DOTA 10H8 minibody was 5.7 +/- 0.1% ID/g, similar to the radioiodinated 10H8 minibody. However, in addition to the expected liver clearance, the kidneys had unexpectedly high activity (34.0 +/- 4.0% ID/g). A minibody derived from a second anti-p185(HER2) antibody (trastuzumab; hu4D5v8) was also made. Tumor uptakes, evaluated by quantitative microPET using 64Cu-DOTA hu4D5v8 minibody, were 4.2 +/- 0.5% ID/g. Furthermore, in non-tumor-bearing mice, 111In-DOTA hu4D5v8 minibody exhibited similar elevated uptake in the kidneys (28.4 +/- 6.5% ID/g). Immunohistochemical staining of kidneys from non-tumor-bearing mice showed strong specific staining of the proximal tubules, and Western blot analysis of kidney lysate confirmed the presence of cross-reactive antigen. To further improve tumor uptake and normal tissue distribution, a larger hu4D5v8 fragment [(scFv-C(H)2-C(H)3)2; 105 kDa] was made, engineered to exhibit rapid clearance kinetics. This fragment, when evaluated by microPET, exhibited improved tumor targeting (12.2 +/- 2.4% ID/g) and reduced kidney uptake (13.1 +/- 1.5% ID/g). Thus, by manipulating the size and format of anti-p185(HER2) antibody fragments, the kidney activity was reduced and high or low expression of p185HER2 in xenografts could be distinguished by microPET imaging.


Related Papers

No related papers found

Powered by citation graph analysis