Design and test of the CMS pixel readout chip
M. Barbero(University of Basel), R. Weber(University of Zurich), G. Dietrich(Paul Scherrer Institute), Beat H. Meier(ETH Zurich), R. Horisberger(California Institute of Technology), W. Erdmann(ETH Zurich), K. Gabathuler(Paul Scherrer Institute), W. Bertl(Paul Scherrer Institute), A. Dorokhov(Paul Scherrer Institute), S. Heising(Paul Scherrer Institute), C. Hörmann(University of Zurich), Hans-Christian Kästli(Paul Scherrer Institute), D. Kotliński(Paul Scherrer Institute)
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
November 2, 2003
Cited by 38
Related Papers
Elastic J/ψ production at HERA
|The European Physical Journal C|2006|316
Characterization of different water pools in solid-state NMR protein samples
|Journal of Biomolecular NMR|2009|294
Nogo-A targeted therapy promotes vascular repair and functional recovery following stroke
|Proceedings of the National Academy of Sciences|2019|150
Deep learning-based behavioral profiling of rodent stroke recovery
|BMC Biology|2022|76