Specific volume measurements of Cu, Mo, Pd, and Ag and calibration of the ruby <i>R</i>1 fluorescence pressure gauge from 0.06 to 1 Mbar

Ho‐kwang Mao(Carnegie Institution for Science), P. M. Bell(Carnegie Institution for Science), J. W. Shaner(Lawrence Livermore National Laboratory), Daniel Steinberg(Lawrence Livermore National Laboratory)
Journal of Applied Physics
June 1, 1978
Cited by 2,252

Abstract

The wavelength shift with pressure of the ruby R1 fluorescence line (Δλ) has been calibrated in the diamond-window pressure cell from 0.06 to 1 Mbar. This was done by simultaneously making specific volume measurements of four metals (Cu, Mo, Ag, and Pd) and referring these results to isothermal equations of state derived from shock-wave experiments. The result is P (Mbar) = (19.04/5) {[(λ0+Δλ)/λ0]5−1}, where λ0 is the wavelength measured at 1 bar.


Related Papers

No related papers found

Powered by citation graph analysis