Mark H. Bilsky(NewYork–Presbyterian Hospital), Ilya Laufer(NewYork–Presbyterian Hospital), Daryl R. Fourney(University of Saskatchewan), Michael W. Groff(Beth Israel Deaconess Medical Center), Meic H. Schmidt(University of Utah), Peter Paul Varga(National Center for Spinal Disorders), Frank D. Vrionis(Moffitt Cancer Center), Yoshiya Yamada(Memorial Sloan Kettering Cancer Center), Peter C. Gerszten(University of Pittsburgh Medical Center), Timothy R. Kuklo(Washington University in St. Louis)
Journal of Neurosurgery Spine
September 1, 2010
Cited by 708

Abstract

OBJECTIVE: The evolution of imaging techniques, along with highly effective radiation options has changed the way metastatic epidural tumors are treated. While high-grade epidural spinal cord compression (ESCC) frequently serves as an indication for surgical decompression, no consensus exists in the literature about the precise definition of this term. The advancement of the treatment paradigms in patients with metastatic tumors for the spine requires a clear grading scheme of ESCC. The degree of ESCC often serves as a major determinant in the decision to operate or irradiate. The purpose of this study was to determine the reliability and validity of a 6-point, MR imaging-based grading system for ESCC. METHODS: To determine the reliability of the grading scale, a survey was distributed to 7 spine surgeons who participate in the Spine Oncology Study Group. The MR images of 25 cervical or thoracic spinal tumors were distributed consisting of 1 sagittal image and 3 axial images at the identical level including T1-weighted, T2-weighted, and Gd-enhanced T1-weighted images. The survey was administered 3 times at 2-week intervals. The inter- and intrarater reliability was assessed. RESULTS: The inter- and intrarater reliability ranged from good to excellent when surgeons were asked to rate the degree of spinal cord compression using T2-weighted axial images. The T2-weighted images were superior indicators of ESCC compared with T1-weighted images with and without Gd. CONCLUSIONS: The ESCC scale provides a valid and reliable instrument that may be used to describe the degree of ESCC based on T2-weighted MR images. This scale accounts for recent advances in the treatment of spinal metastases and may be used to provide an ESCC classification scheme for multicenter clinical trial and outcome studies.


Related Papers

No related papers found

Powered by citation graph analysis