B

Benno J. Rensing

Leiden University

ORCID: 0000-0002-8637-5166

Publishes on Cardiac Imaging and Diagnostics, Coronary Interventions and Diagnostics, Cardiac Valve Diseases and Treatments. 225 papers and 12.6k citations.

225Publications
12.6kTotal Citations

Is this you? Claim your profile.

Add your photo, update your bio, and get notified when your ranking changes.

Top publicationsby citations

Comparison of Platelet Function Tests in Predicting Clinical Outcome in Patients Undergoing Coronary Stent Implantation
Cited by 842

Context High on-treatment platelet reactivity is associated with atherothrombotic events following coronary stent implantation. Objective To evaluate the capability of multiple platelet function tests to predict clinical outcome. Design, Setting, and Patients Prospective, observational, single-center cohort study of 1069 consecutive patients taking clopidogrel undergoing elective coronary stent implantation between December 2005 and December 2007. On-treatment platelet reactivity was measured in parallel by light transmittance aggregometry, Verify Now P2Y12 and Platelet works assays, and the IMPACT-R and the platelet function analysis system (PFA-100) (with the Dade PFA collagen/adenosine diphosphate (ADP) cartridge and Innovance PFA P2Y). Cutoff values for high on-treatment platelet reactivity were established by receiver operating characteristic curve (ROC) analysis. Main Outcome Measurement The primary end point was defined as a composite of all-cause death, nonfatal acute myocardial infarction, stent thrombosis, and ischemic stroke. The primary safety end point included TIMI (Thrombolysis In Myocardial Infarction) criteria major and minor bleeding. Results Kaplan-Meier analysis demonstrated that at 1-year follow-up, the primary end point occurred more frequently in patients with high on-treatment platelet reactivity when assessed by light transmittance aggregometry (52 [11.7%; 95% confidence interval {CI}, 8.9%-15.0%] vs 36 [6.0%;95%CI, 4.2%-8.2%] P.001; n=1049),Verify Now (54 [13.3%; 95% CI, 10.2%-17.0%] vs 37 [5.7%; 95% CI, 4.1%-7.8%]P.001; n=1052), Platelet works (33 [12.6%; 95% CI, 8.8%-17.2%] vs 21 [6.1%;95% CI, 3.8%-9.2%] P=.005; n=606), and Innovance PFA P2Y (18 [12.2%; 95%CI; 7.4%-18.6%] vs 28 [6.3%; 95% CI, 4.3%-8.9%] P=.02; n=588). ROC-curve analysis demonstrated that light transmittance aggregometry (area under the curve[AUC], 0.63; 95% CI, 0.58-0.68), Verify Now (AUC, 0.62; 95% CI, 0.57-0.67), and Platelet works (AUC, 0.61; 95% CI, 0.53-0.69) had modest ability to discriminate between patients with and without primary end point at 1-year follow-up. The IMPACT-R(n=905) and the Siemens PFA Collagen/ADP (n=812) were unable to discriminate between patients with and without the primary end point at 1-year follow-up (all AUCs included 0.50 in the CI). None of the tests identified patients at risk for bleeding. Conclusions Of the platelet function tests assessed, light transmittance aggregometry,Verify Now, Platelet works, and Innovance PFA P2Y were significantly associated with the primary end point. However, the predictive accuracy of these 4 tests was only modest. None of the tests provided accurate prognostic information to identify patients at higher risk of bleeding following stent implantation. Trial Registration clinical trials.gov Identifier: NCT00352014 [corrected].

Sustained Suppression of Neointimal Proliferation by Sirolimus-Eluting Stents
Cited by 671Open Access

BACKGROUND: We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. METHODS AND RESULTS: Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in São Paulo, Brazil (n=30, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the >/=50% diameter stenosis at 1 year by angiography or IVUS assessment, and no edge restenosis was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (2+/-5% obstruction volume, GIII) and at 12 months (GI=2+/-5% and GII=2+/-3%). CONCLUSIONS: This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.