Mount Sinai Hospital
ORCID: 0000-0001-5121-8788Publishes on Genetic factors in colorectal cancer, Colorectal Cancer Screening and Detection, Cancer Genomics and Diagnostics. 159 papers and 10.6k citations.
Add your photo, update your bio, and get notified when your ranking changes.
Intratumoral heterogeneity arises through the evolution of genetically diverse subclones during tumor progression. However, it remains unknown whether cells within single genetic clones are functionally equivalent. By combining DNA copy number alteration (CNA) profiling, sequencing, and lentiviral lineage tracking, we followed the repopulation dynamics of 150 single lentivirus-marked lineages from 10 human colorectal cancers through serial xenograft passages in mice. CNA and mutational analysis distinguished individual clones and showed that clones remained stable upon serial transplantation. Despite this stability, the proliferation, persistence, and chemotherapy tolerance of lentivirally marked lineages were variable within each clone. Chemotherapy promoted the dominance of previously minor or dormant lineages. Thus, apart from genetic diversity, tumor cells display inherent functional variability in tumor propagation potential, which contributes to both cancer growth and therapy tolerance.
UNLABELLED: Failure of liver stiffness measurement (LSM) by transient elastography (TE, FibroScan) and unreliable results occur in ≈ 5% and 15% of patients, respectively, mainly due to obesity. In this multicenter study, we evaluated the feasibility and performance of the novel FibroScan XL probe in 276 patients with chronic liver disease (42% viral hepatitis, 46% nonalcoholic fatty liver disease [NAFLD]) and a body mass index (BMI) ≥ 28 kg/m(2) . Patients underwent liver biopsy and TE with the standard M and XL probes. TE failure was defined as no valid LSMs and unreliable examinations as <10 valid LSMs or an interquartile range (IQR)/LSM >30% or success rate <60%. Probe performance for diagnosing ≥ F2 fibrosis and cirrhosis (F4) versus biopsy were examined using areas under receiver operating characteristic curves (AUROC). FibroScan failure was less frequent with the XL probe than the M probe (1.1% versus 16%) and the XL probe was more often reliable (73% versus 50%; both P < 0.00005). Reliable results with the XL probe were obtained in 61% of patients in whom the M probe was unreliable. Among 178 patients with ≥ 10 valid LSMs using both probes, liver stiffness was highly correlated between probes (ρ = 0.86; P < 0.0005); however, median liver stiffness was lower using the XL probe (6.8 versus 7.8 kPa; P < 0.00005). The AUROC of the XL and M probes were similar for ≥ F2 fibrosis (0.83 versus 0.86; P = 0.19) and cirrhosis (0.94 versus 0.91; P = 0.28). CONCLUSION: Compared with the M probe, the FibroScan XL probe reduces TE failure and facilitates reliable LSM in obese patients. Although the probes have comparable accuracy, lower liver stiffness cutoffs will be necessary when the XL probe is used to noninvasively assess liver fibrosis.