Comparison of Antiarrhythmic Drug Therapy and Radiofrequency Catheter Ablation in Patients With Paroxysmal Atrial FibrillationCONTEXT: Antiarrhythmic drugs are commonly used for prevention of recurrent atrial fibrillation (AF) despite inconsistent efficacy and frequent adverse effects. Catheter ablation has been proposed as an alternative treatment for paroxysmal AF. OBJECTIVE: To determine the efficacy of catheter ablation compared with antiarrhythmic drug therapy (ADT) in treating symptomatic paroxysmal AF. DESIGN, SETTING, AND PARTICIPANTS: A prospective, multicenter, randomized (2:1), unblinded, Bayesian-designed study conducted at 19 hospitals of 167 patients who did not respond to at least 1 antiarrhythmic drug and who experienced at least 3 AF episodes within 6 months before randomization. Enrollment occurred between October 25, 2004, and October 11, 2007, with the last follow-up on January 19, 2009. INTERVENTION: Catheter ablation (n = 106) or ADT (n = 61), with assessment for effectiveness in a comparable 9-month follow-up period. MAIN OUTCOME MEASURES: Time to protocol-defined treatment failure. The proportion of patients who experienced major treatment-related adverse events within 30 days of catheter ablation or ADT was also reported. RESULTS: At the end of the 9-month effectiveness evaluation period, 66% of patients in the catheter ablation group remained free from protocol-defined treatment failure compared with 16% of patients treated with ADT. The hazard ratio of catheter ablation to ADT was 0.30 (95% confidence interval, 0.19-0.47; P < .001). Major 30-day treatment-related adverse events occurred in 5 of 57 patients (8.8%) treated with ADT and 5 of 103 patients (4.9%) treated with catheter ablation. Mean quality of life scores improved significantly in patients treated by catheter ablation compared with ADT at 3 months; improvement was maintained during the course of the study. CONCLUSION: Among patients with paroxysmal AF who had not responded to at least 1 antiarrhythmic drug, the use of catheter ablation compared with ADT resulted in a longer time to treatment failure during the 9-month follow-up period. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00116428.
5-Year Outcomes After Left Atrial Appendage ClosureVivek Y. Reddy, Shephal K. Doshi, Saibal Kar et al.|Journal of the American College of Cardiology|2017 BACKGROUND: The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) trial demonstrated that left atrial appendage closure (LAAC) with the Watchman device (Boston Scientific, St. Paul, Minnesota) was equivalent to warfarin for preventing stroke in atrial fibrillation, but had a high rate of complications. In a second randomized trial, PREVAIL (Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy), the complication rate was low. The warfarin cohort experienced an unexpectedly low ischemic stroke rate, rendering the efficacy endpoints inconclusive. However, these outcomes were based on relatively few patients followed for a relatively short time. OBJECTIVES: The final results of the PREVAIL trial, both alone and as part of a patient-level meta-analysis with the PROTECT AF trial, are reported with patients in both trials followed for 5 years. METHODS: PREVAIL and PROTECT AF are prospective randomized clinical trials with patients randomized 2:1 to LAAC or warfarin; together, they enrolled 1,114 patients for 4,343 patient-years. Analyses are by intention-to-treat, and rates are events per 100 patient-years. RESULTS: For the PREVAIL trial, the first composite coprimary endpoint of stroke, systemic embolism (SE), or cardiovascular/unexplained death did not achieve noninferiority (posterior probability for noninferiority = 88.4%), whereas the second coprimary endpoint of post-procedure ischemic stroke/SE did achieve noninferiority (posterior probability for noninferiority = 97.5%); the warfarin arm maintained an unusually low ischemic stroke rate (0.73%). In the meta-analysis, the composite endpoint was similar between groups (hazard ratio [HR]: 0.820; p = 0.27), as were all-stroke/SE (HR: 0.961; p = 0.87). The ischemic stroke/SE rate was numerically higher with LAAC, but this difference did not reach statistical significance (HR: 1.71; p = 0.080). However, differences in hemorrhagic stroke, disabling/fatal stroke, cardiovascular/unexplained death, all-cause death, and post-procedure bleeding favored LAAC (HR: 0.20; p = 0.0022; HR: 0.45; p = 0.03; HR: 0.59; p = 0.027; HR: 0.73; p = 0.035; HR: 0.48; p = 0.0003, respectively). CONCLUSIONS: These 5-year outcomes of the PREVAIL trial, combined with the 5-year outcomes of the PROTECT AF trial, demonstrate that LAAC with Watchman provides stroke prevention in nonvalvular atrial fibrillation comparable to warfarin, with additional reductions in major bleeding, particularly hemorrhagic stroke, and mortality. (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation; NCT00129545; and Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy; NCT01182441).
Percutaneous Left Atrial Appendage Closure vs Warfarin for Atrial FibrillationIMPORTANCE: While effective in preventing stroke in patients with atrial fibrillation (AF), warfarin is limited by a narrow therapeutic profile, a need for lifelong coagulation monitoring, and multiple drug and diet interactions. OBJECTIVE: To determine whether a local strategy of mechanical left atrial appendage (LAA) closure was noninferior to warfarin. DESIGN, SETTING, AND PARTICIPANTS: PROTECT AF was a multicenter, randomized (2:1), unblinded, Bayesian-designed study conducted at 59 hospitals of 707 patients with nonvalvular AF and at least 1 additional stroke risk factor (CHADS2 score ≥1). Enrollment occurred between February 2005 and June 2008 and included 4-year follow-up through October 2012. Noninferiority required a posterior probability greater than 97.5% and superiority a probability of 95% or greater; the noninferiority margin was a rate ratio of 2.0 comparing event rates between treatment groups. INTERVENTIONS: Left atrial appendage closure with the device (n = 463) or warfarin (n = 244; target international normalized ratio, 2-3). MAIN OUTCOMES AND MEASURES: A composite efficacy end point including stroke, systemic embolism, and cardiovascular/unexplained death, analyzed by intention-to-treat. RESULTS: At a mean (SD) follow-up of 3.8 (1.7) years (2621 patient-years), there were 39 events among 463 patients (8.4%) in the device group for a primary event rate of 2.3 events per 100 patient-years, compared with 34 events among 244 patients (13.9%) for a primary event rate of 3.8 events per 100 patient-years with warfarin (rate ratio, 0.60; 95% credible interval, 0.41-1.05), meeting prespecified criteria for both noninferiority (posterior probability, >99.9%) and superiority (posterior probability, 96.0%). Patients in the device group demonstrated lower rates of both cardiovascular mortality (1.0 events per 100 patient-years for the device group [17/463 patients, 3.7%] vs 2.4 events per 100 patient-years with warfarin [22/244 patients, 9.0%]; hazard ratio [HR], 0.40; 95% CI, 0.21-0.75; P = .005) and all-cause mortality (3.2 events per 100 patient-years for the device group [57/466 patients, 12.3%] vs 4.8 events per 100 patient-years with warfarin [44/244 patients, 18.0%]; HR, 0.66; 95% CI, 0.45-0.98; P = .04). CONCLUSIONS AND RELEVANCE: After 3.8 years of follow-up among patients with nonvalvular AF at elevated risk for stroke, percutaneous LAA closure met criteria for both noninferiority and superiority, compared with warfarin, for preventing the combined outcome of stroke, systemic embolism, and cardiovascular death, as well as superiority for cardiovascular and all-cause mortality. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00129545.
Prophylactic Catheter Ablation for the Prevention of Defibrillator TherapyVivek Y. Reddy, Matthew R. Reynolds, Petr Neužil et al.|New England Journal of Medicine|2007 BACKGROUND: For patients who have a ventricular tachyarrhythmic event, implantable cardioverter-defibrillators (ICDs) are a mainstay of therapy to prevent sudden death. However, ICD shocks are painful, can result in clinical depression, and do not offer complete protection against death from arrhythmia. We designed this randomized trial to examine whether prophylactic radiofrequency catheter ablation of arrhythmogenic ventricular tissue would reduce the incidence of ICD therapy. METHODS: Eligible patients with a history of a myocardial infarction underwent defibrillator implantation for spontaneous ventricular tachycardia or fibrillation. The patients did not receive antiarrhythmic drugs. Patients were randomly assigned to defibrillator implantation alone or defibrillator implantation with adjunctive catheter ablation (64 patients in each group). Ablation was performed with the use of a substrate-based approach in which the myocardial scar is mapped and ablated while the heart remains predominantly in sinus rhythm. The primary end point was survival free from any appropriate ICD therapy. RESULTS: The mortality rate 30 days after ablation was zero, and there were no significant changes in ventricular function or functional class during the mean (+/-SD) follow-up period of 22.5+/-5.5 months. Twenty-one patients assigned to defibrillator implantation alone (33%) and eight patients assigned to defibrillator implantation plus ablation (12%) received appropriate ICD therapy (antitachycardia pacing or shocks) (hazard ratio in the ablation group, 0.35; 95% confidence interval, 0.15 to 0.78, P=0.007). Among these patients, 20 in the control group (31%) and 6 in the ablation group (9%) received shocks (P=0.003). Mortality was not increased in the group assigned to ablation as compared with the control group (9% vs. 17%, P=0.29). CONCLUSIONS: In this randomized trial, prophylactic substrate-based catheter ablation reduced the incidence of ICD therapy in patients with a history of myocardial infarction who received ICDs for the secondary prevention of sudden death. (Current Controlled Trials number, ISRCTN62488166 [controlled-trials.com].).
A Leadless Intracardiac Transcatheter Pacing SystemDwight Reynolds, Gábor Zoltán Duray, Razali Omar et al.|New England Journal of Medicine|2015 BACKGROUND: A leadless intracardiac transcatheter pacing system has been designed to avoid the need for a pacemaker pocket and transvenous lead. METHODS: In a prospective multicenter study without controls, a transcatheter pacemaker was implanted in patients who had guideline-based indications for ventricular pacing. The analysis of the primary end points began when 300 patients reached 6 months of follow-up. The primary safety end point was freedom from system-related or procedure-related major complications. The primary efficacy end point was the percentage of patients with low and stable pacing capture thresholds at 6 months (≤2.0 V at a pulse width of 0.24 msec and an increase of ≤1.5 V from the time of implantation). The safety and efficacy end points were evaluated against performance goals (based on historical data) of 83% and 80%, respectively. We also performed a post hoc analysis in which the rates of major complications were compared with those in a control cohort of 2667 patients with transvenous pacemakers from six previously published studies. RESULTS: The device was successfully implanted in 719 of 725 patients (99.2%). The Kaplan-Meier estimate of the rate of the primary safety end point was 96.0% (95% confidence interval [CI], 93.9 to 97.3; P<0.001 for the comparison with the safety performance goal of 83%); there were 28 major complications in 25 of 725 patients, and no dislodgements. The rate of the primary efficacy end point was 98.3% (95% CI, 96.1 to 99.5; P<0.001 for the comparison with the efficacy performance goal of 80%) among 292 of 297 patients with paired 6-month data. Although there were 28 major complications in 25 patients, patients with transcatheter pacemakers had significantly fewer major complications than did the control patients (hazard ratio, 0.49; 95% CI, 0.33 to 0.75; P=0.001). CONCLUSIONS: In this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system while providing low and stable pacing thresholds. (Funded by Medtronic; Micra Transcatheter Pacing Study ClinicalTrials.gov number, NCT02004873.).