Pressure Dependence of Fragile-to-Strong Transition and a Possible Second Critical Point in Supercooled Confined WaterLi Liu, Sow‐Hsin Chen, Antonio Faraone et al.|Physical Review Letters|2005 By confining water in nanopores of silica glass, we can bypass the crystallization and study the pressure effect on the dynamical behavior in deeply supercooled state using neutron scattering. We observe a clear evidence of a cusplike fragile-to-strong (FS) dynamic transition. Here we show that the transition temperature decreases steadily with an increasing pressure, until it intersects the homogenous nucleation temperature line of bulk water at a pressure of 1600 bar. Above this pressure, it is no longer possible to discern the characteristic feature of the FS transition. Identification of this end point with the possible second critical point is discussed.
Fragile-to-strong liquid transition in deeply supercooled confined waterAntonio Faraone, L. Liu, Chung‐Yuan Mou et al.|The Journal of Chemical Physics|2004 Confining water in lab synthesized nanoporous silica matrices MCM-41-S with pore diameters of 18 and 14 A, we have been able to study the molecular dynamics of water in deeply supercooled states, down to 200 K. Using quasielastic neutron scattering and analyzing the data with the relaxing cage model, we determined the temperature variation of the average translational relaxation time and its Q-dependence. We find a clear evidence of an abrupt change of the relaxation time behavior at T approximately equal to 225 K, which we interpreted as the predicted fragile-to-strong liquid-liquid transition.
Multicolored silver nanoparticles for multiplexed disease diagnostics: distinguishing dengue, yellow fever, and Ebola virusesRapid point-of-care (POC) diagnostic devices are needed for field-forward screening of severe acute systemic febrile illnesses. Multiplexed rapid lateral flow diagnostics have the potential to distinguish among multiple pathogens, thereby facilitating diagnosis and improving patient care. Here, we present a platform for multiplexed pathogen detection using multi-colored silver nanoplates. This design requires no external excitation source and permits multiplexed analysis in a single channel, facilitating integration and manufacturing.
Rapid antigen tests for dengue virus serotypes and Zika virus in patient serumIrene Bosch, Helena de Puig, Megan Hiley et al.|Science Translational Medicine|2017 The recent Zika virus (ZIKV) outbreak demonstrates that cost-effective clinical diagnostics are urgently needed to detect and distinguish viral infections to improve patient care. Unlike dengue virus (DENV), ZIKV infections during pregnancy correlate with severe birth defects, including microcephaly and neurological disorders. Because ZIKV and DENV are related flaviviruses, their homologous proteins and nucleic acids can cause cross-reactions and false-positive results in molecular, antigenic, and serologic diagnostics. We report the characterization of monoclonal antibody pairs that have been translated into rapid immunochromatography tests to specifically detect the viral nonstructural 1 (NS1) protein antigen and distinguish the four DENV serotypes (DENV1-4) and ZIKV without cross-reaction. To complement visual test analysis and remove user subjectivity in reading test results, we used image processing and data analysis for data capture and test result quantification. Using a 30-μl serum sample, the sensitivity and specificity values of the DENV1-4 tests and the pan-DENV test, which detects all four dengue serotypes, ranged from 0.76 to 1.00. Sensitivity/specificity for the ZIKV rapid test was 0.81/0.86, respectively, using a 150-μl serum input. Serum ZIKV NS1 protein concentrations were about 10-fold lower than corresponding DENV NS1 concentrations in infected patients; moreover, ZIKV NS1 protein was not detected in polymerase chain reaction-positive patient urine samples. Our rapid immunochromatography approach and reagents have immediate application in differential clinical diagnosis of acute ZIKV and DENV cases, and the platform can be applied toward developing rapid antigen diagnostics for emerging viruses.
Extinction Coefficient of Gold NanostarsHelena de Puig, Justina Tam, Chun‐Wan Yen et al.|The Journal of Physical Chemistry C|2015 Gold nanostars (NStars) are highly attractive for biological applications due to their surface chemistry, facile synthesis, and optical properties. Here, we synthesize NStars in HEPES buffer at different HEPES/Au ratios, producing NStars of different sizes and shapes and therefore varying optical properties. We measure the extinction coefficient of the synthesized NStars at their maximum surface plasmon resonances (SPRs), which range from 5.7 × 108 to 26.8 × 108 M–1 cm–1. Measured values correlate with those obtained from theoretical models of the NStars using the discrete dipole approximation (DDA), which we use to simulate the extinction spectra of the nanostars. Finally, because NStars are typically used in biological applications, we conjugate DNA and antibodies to the NStars and calculate the footprint of the bound biomolecules.